Literature DB >> 10828190

Changes in ADC caused by tensile loading of rabbit achilles tendon: evidence for water transport.

S Han1, S J Gemmell, K G Helmer, P Grigg, J W Wellen, A H Hoffman, C H Sotak.   

Abstract

Water diffusion measurements were performed on rabbit Achilles tendons during static tensile loading and tendons in an unloaded state. The apparent diffusion coefficient (ADC) was measured along two directions: parallel and perpendicular to the long axis of the tendon. Tendons were studied after being prepared in two ways: (a) after being stored frozen in phosphate-buffered saline (PBS) and (b) freshly isolated. Statistically significant directional anisotropy was observed in the ADC in all tendons. The ADC was significantly greater in the direction parallel to the long axis of the tendon than in the perpendicular direction. The anisotropy is attributed to the greater restrictions seen by the water molecules in the perpendicular direction and is consistent with the known geometry of the tendon. Storage in PBS caused tendons to swell. This increased the ADC measured along both directions and reduced the anisotropy. The existence of anisotropy in the ADC was not related to the orientation of the specimen in the magnet. The ADC increased along both directions following the application of a 5-N tensile load; the increase was greatest along the perpendicular axis of the tendon. In order to determine whether load-related changes in the ADC reflected changes in interfibrilar spacing, we used electron microscopy to measure load-related changes in fibril spacing. Load-related changes in fiber spacing could not account for the observed changes in the ADC. The increase in ADC caused by loading was attributed to the extrusion of tendon water into a bulk phase along the outside surface of the tendon. In PBS-stored samples, enough fluid was extruded that it could be visualized. The transient response of the ADC to a 5-N tensile load was also studied. The absolute ADC in both directions increased with loading and recovered to baseline upon unloading. The transient changes in ADC, for both loading and unloading, had a mean time constant of approximately 15 min. The magnitude of the load-induced transient ADC changes was comparable to that seen in the static-loading experiments. Copyright 2000 Academic Press.

Entities:  

Mesh:

Year:  2000        PMID: 10828190     DOI: 10.1006/jmre.2000.2075

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  14 in total

1.  Diffusional anisotropy in collagenous tissues: fluorescence imaging of continuous point photobleaching.

Authors:  Holly A Leddy; Mansoor A Haider; Farshid Guilak
Journal:  Biophys J       Date:  2006-04-07       Impact factor: 4.033

2.  Three-dimensional fibril-reinforced finite element model of articular cartilage.

Authors:  L P Li; J T M Cheung; W Herzog
Journal:  Med Biol Eng Comput       Date:  2009-03-06       Impact factor: 2.602

3.  Micromechanical poroelastic finite element and shear-lag models of tendon predict large strain dependent Poisson's ratios and fluid expulsion under tensile loading.

Authors:  Hossein Ahmadzadeh; Benjamin R Freedman; Brianne K Connizzo; Louis J Soslowsky; Vivek B Shenoy
Journal:  Acta Biomater       Date:  2015-04-29       Impact factor: 8.947

4.  Effect of sulfated glycosaminoglycan digestion on the transverse permeability of medial collateral ligament.

Authors:  Heath B Henninger; Clayton J Underwood; Gerard A Ateshian; Jeffrey A Weiss
Journal:  J Biomech       Date:  2010-06-08       Impact factor: 2.712

5.  Ultrashort echo time T2 values decrease in tendons with application of static tensile loads.

Authors:  Saeed Jerban; Amin Nazaran; Xin Cheng; Michael Carl; Nikolaus Szeverenyi; Jiang Du; Eric Y Chang
Journal:  J Biomech       Date:  2017-07-25       Impact factor: 2.712

6.  Time-dependent ultrasound echo changes occur in tendon during viscoelastic testing.

Authors:  Sarah Duenwald-Kuehl; Hirohito Kobayashi; Roderic Lakes; Ray Vanderby
Journal:  J Biomech Eng       Date:  2012-11       Impact factor: 2.097

7.  Layer-specific intracortical connectivity revealed with diffusion MRI.

Authors:  Christoph W U Leuze; Alfred Anwander; Pierre-Louis Bazin; Bibek Dhital; Carsten Stüber; Katja Reimann; Stefan Geyer; Robert Turner
Journal:  Cereb Cortex       Date:  2012-10-25       Impact factor: 5.357

8.  Solid-state NMR reveals structural and dynamical properties of a membrane-anchored electron-carrier protein, cytochrome b5.

Authors:  Ulrich H N Dürr; Kazutoshi Yamamoto; Sang-Choul Im; Lucy Waskell; Ayyalusamy Ramamoorthy
Journal:  J Am Chem Soc       Date:  2007-05-09       Impact factor: 15.419

9.  Structural biomechanics modulate intramuscular distribution of locally delivered drugs.

Authors:  Peter I-Kung Wu; Elazer R Edelman
Journal:  J Biomech       Date:  2008-08-15       Impact factor: 2.712

10.  Structural changes in loaded equine tendons can be monitored by a novel spectroscopic technique.

Authors:  Oksana Kostyuk; Helen L Birch; Vivek Mudera; Robert A Brown
Journal:  J Physiol       Date:  2003-10-24       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.