Literature DB >> 10828187

Anisotropy in tendon investigated in vivo by a portable NMR scanner, the NMR-MOUSE.

R Haken1, B Blümich.   

Abstract

Ordered tissue like tendon is known to exhibit the magic-angle phenomenon in magnetic resonance investigations. Due to the anisotropic structure the transverse relaxation time T(2) depends on the orientation of the tendon in the magnetic field. In medical imaging, relaxation measurements of tendon orientation are restricted by the size of the object and the space available in the magnet. For humans, tendon orientation can only be varied within small limits. As a consequence, the magic-angle phenomenon may lead to a misjudgement of tendon condition. It is demonstrated that the NMR-MOUSE (mobile universal surface explorer), a hand-held NMR sensor, can be employed to investigate the anisotropy of T(2) in Achilles tendon in vivo. The NMR-MOUSE provides a convenient tool for analyzing the correlation of T(2) and the physical condition of tendon. Copyright 2000 Academic Press.

Entities:  

Mesh:

Year:  2000        PMID: 10828187     DOI: 10.1006/jmre.2000.2040

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  13 in total

1.  Further studies on the anisotropic distribution of collagen in articular cartilage by μMRI.

Authors:  ShaoKuan Zheng; Yang Xia; Farid Badar
Journal:  Magn Reson Med       Date:  2010-10-11       Impact factor: 4.668

2.  Anisotropic analysis of multi-component T2 and T1ρ relaxations in achilles tendon by NMR spectroscopy and microscopic MRI.

Authors:  Nian Wang; Yang Xia
Journal:  J Magn Reson Imaging       Date:  2013-01-24       Impact factor: 4.813

3.  Real-time measurement of diffusion exchange rate in biological tissue.

Authors:  Nathan H Williamson; Rea Ravin; Teddy X Cai; Dan Benjamini; Melanie Falgairolle; Michael J O'Donovan; Peter J Basser
Journal:  J Magn Reson       Date:  2020-07-08       Impact factor: 2.229

4.  Anisotropic mechanical properties of magnetically aligned fibrin gels measured by magnetic resonance elastography.

Authors:  Ravi Namani; Matthew D Wood; Shelly E Sakiyama-Elbert; Philip V Bayly
Journal:  J Biomech       Date:  2009-08-05       Impact factor: 2.712

5.  Experimental issues in the measurement of multi-component relaxation times in articular cartilage by microscopic MRI.

Authors:  Nian Wang; Yang Xia
Journal:  J Magn Reson       Date:  2013-07-15       Impact factor: 2.229

6.  The collagen fibril structure in the superficial zone of articular cartilage by microMRI.

Authors:  S Zheng; Y Xia
Journal:  Osteoarthritis Cartilage       Date:  2009-06-23       Impact factor: 6.576

7.  Observation of Angular Dependence of T1 in the Human White Matter at 3T.

Authors:  Michael J Knight; Robin A Damion; Risto A Kauppinen
Journal:  Biomed Spectrosc Imaging       Date:  2019-01-24

Review 8.  Recent advances in 3D bioprinting of musculoskeletal tissues.

Authors:  Tyler Potyondy; Jorge Alfredo Uquillas; Peyton J Tebon; Batzaya Byambaa; Anwarul Hasan; Maryam Tavafoghi; Heloise Mary; George E Aninwene; Ippokratis Pountos; Ali Khademhosseini; Nureddin Ashammakhi
Journal:  Biofabrication       Date:  2021-03-10       Impact factor: 9.954

Review 9.  Characterization of Structural Bone Properties through Portable Single-Sided NMR Devices: State of the Art and Future Perspectives.

Authors:  Marco Barbieri; Paola Fantazzini; Claudia Testa; Villiam Bortolotti; Fabio Baruffaldi; Feliks Kogan; Leonardo Brizi
Journal:  Int J Mol Sci       Date:  2021-07-07       Impact factor: 5.923

10.  Degradation of phosphate ester hydraulic fluid in power station turbines investigated by a three-magnet unilateral magnet array.

Authors:  Pan Guo; Wei He; Juan C García-Naranjo
Journal:  Sensors (Basel)       Date:  2014-04-14       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.