Literature DB >> 10819280

Osteocutaneous radial forearm free flaps. The necessity of internal fixation of the donor-site defect to prevent pathological fracture.

K W Bowers1, J L Edmonds, D A Girod, G Jayaraman, C P Chua, E B Toby.   

Abstract

BACKGROUND: Osteocutaneous radial forearm free flaps have fallen from favor due to pathological fractures of the radius. The purposes of this study were to propose a means to decrease the rate of pathological fracture by prophylactic fixation of the donor-site defect and to evaluate this technique biomechanically.
METHODS: Two groups of ten matched pairs of fresh-frozen cadaveric radii were harvested. In Group 1, an eight-centimeter length of radius comprising 50 percent of the cross-sectional area of the bone was removed to simulate an osteocutaneous radial forearm donor-site defect. This defect was created in one member of each pair, with the other bone in the pair left intact. In Group 2, both members of the ten matched pairs of radii had identical defects created as previously described. However, one radius in each pair had a twelve-hole, 3.5-millimeter dynamic compression plate placed across the segmental defect. In each group, five matched pairs were tested to failure in torsion and five matched pairs were tested to failure in four-point bending.
RESULTS: In Group 1, the intact radius was a mean of 5.7 times stronger in torsion and 4.2 times stronger in four-point bending than the radius with the segmental resection. In Group 2, the radius that was ostectomized and fixed with a plate was a mean of 4.0 times stronger in torsion and 2.7 times stronger in four-point bending than the ostectomized radius.
CONCLUSIONS: Removal of an eight-centimeter segment from the radius dramatically decreased both torsion and bending strength. Application of a plate over the defect in the radius significantly restored the strength of the radius (p = 0.01).

Entities:  

Mesh:

Year:  2000        PMID: 10819280

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  4 in total

1.  In vivo performance of bilayer hydroxyapatite scaffolds for bone tissue regeneration in the rabbit radius.

Authors:  Teja Guda; John A Walker; Beth E Pollot; Mark R Appleford; Sunho Oh; Joo L Ong; Joseph C Wenke
Journal:  J Mater Sci Mater Med       Date:  2011-02-02       Impact factor: 3.896

2.  Assessment of donor site morbidity for free radial forearm osteocutaneous flaps.

Authors:  Catherine F Sinclair; John P Gleysteen; Terence M Zimmermann; Mark K Wax; Babak Givi; Daniel Schneider; Eben L Rosenthal
Journal:  Microsurgery       Date:  2012-03-31       Impact factor: 2.425

3.  Association of the Anterolateral Thigh Osteomyocutaneous Flap With Femur Structural Integrity and Assessment of Prophylactic Fixation.

Authors:  Mitchell L Worley; Travis M Patterson; Evan M Graboyes; Yongren Wu; Robert M Brody; Joshua Hornig; Zeke Walton
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2018-09-01       Impact factor: 6.223

4.  The use of the radial styloid in the extended osteocutaneous radial forearm free flap.

Authors:  Jennifer Matthews; Wendy Ng; Stuart Archibald; Carolyn Levis
Journal:  Plast Surg (Oakv)       Date:  2016-05-27       Impact factor: 0.947

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.