Literature DB >> 10813860

Assessment of cerebral gliomas by a new dark fluid sequence, high intensity REduction (HIRE): a preliminary study.

M Essig1, M Deimling, H Hawighorst, J Debus, G van Kaick.   

Abstract

The purpose of this study was to assess the diagnostic potential of a new dark fluid sequence, high intensity reduction (HIRE) in the diagnostic workup of patients with cerebral gliomas. The HIRE sequence utilizes a very long T(2) value of the cerebrospinal fluid (CSF) to suppress its high signal contribution in T(2)-weighted imaging by a image subtraction technique. Fifteen patients with histologically confirmed cerebral gliomas were examined with T(2)-weighted fast spin-echo (FSE), T(1)-weighted SE, fast fluid-attenuated inversion recovery (FLAIR), and HIRE imaging using identical scan parameters. In patients with enhancing lesions, fast FLAIR and HIRE were added to the contrast-enhanced T(1)-weighted SE images. Images were analyzed in a qualitative and quantitative evaluation. In the qualitative analysis, lesion detection, lesion delineation, and differentiation between enhancing and non-enhancing tumor tissue were assessed in a two-reader study. For the quantitative analysis, lesion-to-background and lesion-to-CSF contrast and contrast-to-noise ratios were determined in a region of interest analysis. HIRE achieved a significant reduction of the CSF signal without losing the high gray-to-white matter contrast of T(2)-weighted sequences. In the quantitative analysis, the contrast ratios of the HIRE images were lower compared with the FLAIR images due to a relatively high background and CSF signal. After administration of contrast media, HIRE images presented a significant signal increase in enhancing lesions, which subsequently increased the contrast and contrast-to-noise ratios. In the qualitative analysis, both readers found all tumors clearly delineated on HIRE imaging. Compared with T(2)-weighted FSE, the tumor delineation with HIRE was better in nine patients, equal in four patients, and less in one patient. Compared with the FLAIR images, HIRE was rated superior in three patients, equal in nine patients, and inferior in another three patients. Delineation of the enhancing tumor parts was possible with HIRE in all patients. HIRE images had significantly fewer image artifacts than FLAIR images due to reduced inflow effects. The T(2)-based HIRE sequence presented is an alternative to the T(1)-based FLAIR sequence, with the advantage of better gray-to-white matter contrast and shorter measurement time. Due to the subtraction technique, signal intensities from tissues with relaxation times in the range T(2 WM) < < T(2) < T(2 CSF) are also gradually affected, corresponding to their T(2) values. With respect to this unwanted effect, an improvement in HIRE imaging will be possible by using a self-weighted subtraction algorithm. In a forthcoming study this concept will first be tested on appropriate phantom fluids.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10813860     DOI: 10.1002/(sici)1522-2586(200005)11:5<506::aid-jmri6>3.0.co;2-d

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  Improved short tau inversion recovery (iSTIR) for increased tumor conspicuity in the abdomen.

Authors:  Ananth J Madhuranthakam; Karen S Lee; Aya Yassin; Jean H Brittain; Ivan Pedrosa; Neil M Rofsky; David C Alsop
Journal:  MAGMA       Date:  2013-09-20       Impact factor: 2.310

Review 2.  Use of Multiplied, Added, Subtracted and/or FiTted Inversion Recovery (MASTIR) pulse sequences.

Authors:  Ya-Jun Ma; Shujuan Fan; Hongda Shao; Jiang Du; Nikolaus M Szeverenyi; Ian R Young; Graeme M Bydder
Journal:  Quant Imaging Med Surg       Date:  2020-06

3.  Whole-body MRI for metastatic cancer detection using T2 -weighted imaging with fat and fluid suppression.

Authors:  Xinzeng Wang; Ali Pirasteh; James Brugarolas; Neil M Rofsky; Robert E Lenkinski; Ivan Pedrosa; Ananth J Madhuranthakam
Journal:  Magn Reson Med       Date:  2018-02-14       Impact factor: 4.668

4.  Reduction of CSF and blood flow artifacts on FLAIR images of the brain with k-space reordered by inversion time at each slice position (KRISP).

Authors:  A H Herlihy; J V Hajnal; W L Curati; N Virji; A Oatridge; B K Puri; G M Bydder
Journal:  AJNR Am J Neuroradiol       Date:  2001-05       Impact factor: 3.825

5.  Synthetic MRI with T2-based Water Suppression to Reduce Hyperintense Artifacts due to CSF-Partial Volume Effects in the Brain.

Authors:  Tokunori Kimura; Kousuke Yamashita; Kouta Fukatsu
Journal:  Magn Reson Med Sci       Date:  2020-10-16       Impact factor: 2.471

6.  Diffusion MR Imaging with T2-based Water Suppression (T2wsup-dMRI).

Authors:  Tokunori Kimura; Kousuke Yamashita; Kouta Fukatsu
Journal:  Magn Reson Med Sci       Date:  2021-08-03       Impact factor: 2.760

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.