Literature DB >> 108104

A whole body counter with an invariant response for whole body analysis.

P Mariss, E Jahns, O Schober.   

Abstract

A scanning 6-detector whole body counter is described. Its characteristics include good sensitivity, high energy resolution, good counting efficiency, geometric uniformity and localisation information of incorporated radioactivity using collimators. Problems such as band-width, calibration for air and phantom and measurements on patients, are discussed. The whole body counter is compared to other systems.

Entities:  

Mesh:

Year:  1978        PMID: 108104     DOI: 10.1007/bf00251638

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  16 in total

1.  Evaluation of linear profile scans; mathematical treatment of line-spread functions.

Authors:  O Schober; E Jahns; P Mariss
Journal:  Eur J Nucl Med       Date:  1978-04-01

2.  The quantitative determination of iron kinetics and hemoglobin synthesis in human subjects.

Authors:  M POLLYCOVE; R MORTIMER
Journal:  J Clin Invest       Date:  1961-05       Impact factor: 14.808

3.  Accurate whole-body quantitation of 131-I retention by counting a scatter window.

Authors:  W D Gibbs; H D Hodges; M Bailey; C C Lushbaugh
Journal:  J Nucl Med       Date:  1970-08       Impact factor: 10.057

4.  A whole-body counter with an invariant response to radionuclide distribution and body size.

Authors:  S H Cohn; C S Dombrowski; H R Pate; J S Robertson
Journal:  Phys Med Biol       Date:  1969-10       Impact factor: 3.609

5.  Comparison of techniques for whole-body counting of gamma-ray emitting nuclides with NaI(T1) detectors. I. Point sources in phantoms.

Authors:  R A Dudley; A Ben Haim
Journal:  Phys Med Biol       Date:  1968-04       Impact factor: 3.609

6.  [Whole-body measurement by means of NaI crystals. Sensitivity and accuracy of measurement with various detector arrangements].

Authors:  C Schneider; W A Linden
Journal:  Strahlentherapie       Date:  1967-06

7.  [Whole-body activity counter. Part 1: physical-technological principles].

Authors:  P Koeppe
Journal:  Radiobiol Radiother (Berl)       Date:  1975

8.  A high sensitivity dual-detector shadow-shield whole-body counter with an 'invariant' response for total body in vivo neutron activation analysis.

Authors:  K Boddy; A Elliott; I Robertson; M E Mahaffy; I Holloway
Journal:  Phys Med Biol       Date:  1975-03       Impact factor: 3.609

9.  Whole-body measurement techniques at the Swedish National Institute of Radiation Protection.

Authors:  R Falk; A Magi; G A Swedjemark
Journal:  Acta Radiol Suppl       Date:  1971

10.  A whole-body counter for clinical measurements utilizing the 'shadow shield' technique.

Authors:  G T Warner; R Oliver
Journal:  Phys Med Biol       Date:  1966-01       Impact factor: 3.609

View more
  5 in total

1.  Evaluation of one dimensional profile scans with a whole body counter--82bromide space in liver cirrhosis: concise communication.

Authors:  O Schober; B Knoop; P Mariss; K Jordan; H Hundeshagen; F W Schmidt
Journal:  Eur J Nucl Med       Date:  1979-06-01

2.  Evaluation of linear profile scans; mathematical treatment of line-spread functions.

Authors:  O Schober; E Jahns; P Mariss
Journal:  Eur J Nucl Med       Date:  1978-04-01

3.  Altered potassium homeostasis in Crohn's disease.

Authors:  O Schober; C Bossaller; L Lehr; H Hundeshagen
Journal:  Eur J Nucl Med       Date:  1983

4.  Total body water, extracellular water, plasma volume, and total body potassium in cirrhosis of the liver.

Authors:  O Schober; P Mariss; F W Schmidt; H Hundeshagen
Journal:  Klin Wochenschr       Date:  1979-08-01

5.  Total body potassium depletion and the need for preoperative nutritional support in Chrohn's disease.

Authors:  K Lehr; O Schober; H Hundeshagen; R Pichlmayr
Journal:  Ann Surg       Date:  1982-12       Impact factor: 12.969