Literature DB >> 10807451

Exploiting rate-related hysteresis in repolarization alternans to improve risk stratification for ventricular tachycardia.

S M Narayan1, J M Smith.   

Abstract

OBJECTIVES: We sought to study the effect of heart rate acceleration and deceleration on the ability of repolarization alternans (RPA) to stratify ventricular tachycardia (VT) risk.
BACKGROUND: Heart rate fluctuations alter arrhythmic propensity, yet it is unclear whether fluctuations, as well as absolute rate, dynamically increase VT risk. We hypothesized that repolarization heterogeneity reflected by RPA would exhibit hysteresis during rising and falling heart rate, which may reflect arrhythmic propensity.
METHODS: The RPA magnitude (absolute voltage of alternation [V(alt)] and T-wave alternans ratio [TWAR]) and temporal distribution were determined from the electrocardiogram (ECG) in 60 patients during paced heart rate acceleration from 100 to 150 beats/min, then deceleration to 100 beats/min at electrophysiologic study (EPS). The V(alt) and TWAR thresholds were varied prospectively to generate receiver-operating characteristics (ROC) for the prediction of inducible VT at EPS.
RESULTS: Thirty-six patients were induced into VT and 24 were not. Hysteresis of RPA was seen. The V(alt) reached steady-state within 60 beats of each rate transition and was higher in deceleration than in acceleration at matched heart rates. In induced patients, V(alt) rose then fell with heart rate. In noninduced patients, V(alt) was insensitive to acceleration, but rose on initial deceleration. The RPA distributed later within repolarization in induced patients but, on deceleration, moved earlier in both groups. By ROC analysis, V(alt) = 2.6 microV in late repolarization at 120 beats/min provided optimal sensitivity and specificity for VT in acceleration (87.5% and 88.7%, respectively) versus deceleration (80% and 62.5%, respectively; p = 0.004, chi-square test).
CONCLUSIONS: 1) Physiologic fluctuations in heart rate may affect the clinical utility of RPA for VT risk stratification; and 2) repolarization dispersion measured by RPA is more exaggerated during deceleration than acceleration at matched heart rates (rate hysteresis).

Entities:  

Mesh:

Year:  2000        PMID: 10807451     DOI: 10.1016/s0735-1097(00)00580-5

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  4 in total

Review 1.  T-wave alternans testing for ventricular arrhythmias.

Authors:  Sanjiv M Narayan
Journal:  Prog Cardiovasc Dis       Date:  2008 Sep-Oct       Impact factor: 8.194

2.  Heart Rate-Dependent Hysteresis of T-Wave Alternans in Primary Prevention ICD Patients.

Authors:  Laura Burattini; Sumche Man; Sandro Fioretti; Francesco Di Nardo; Cees A Swenne
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-12-16       Impact factor: 1.468

3.  Current developments in microvolt T-wave alternans.

Authors:  Beata Sredniawa; Agata Musialik-Lydka; Jacek Kowalczyk; Zbigniew Kalarus
Journal:  Indian Pacing Electrophysiol J       Date:  2006-10-01

Review 4.  Cardiac dynamics: Alternans and arrhythmogenesis.

Authors:  Gary Tse; Sheung Ting Wong; Vivian Tse; Yee Ting Lee; Hiu Yu Lin; Jie Ming Yeo
Journal:  J Arrhythm       Date:  2016-03-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.