BACKGROUND: Human peripheral blood lymphocytes kept in culture after isolation die by an apoptotic process. Detection of apoptosis with labeled Annexin V to demonstrate loss of plasma membrane asymmetry is sensitive, specific, and easy using flow cytometry. This is true in lymphoblastic cell lines when combining Annexin V-fluorescein isothiocyanate (FITC) and propidium iodide (PI). However, measurement of apoptosis by flow cytometry in isolated human lymphocytes using Annexin V-FITC/PI is disturbed by the presence of a variable percentage of erythrocytes in the isolated lymphocyte population. To overcome this problem, we have developed and tested a new four-color flow cytometric assay to detect apoptosis in lymphocyte subsets of cultured peripheral blood cells. METHODS: Peripheral blood lymphocytes are isolated by density gradient centrifugation. Nucleus-containing cells are selected using CD45-phycoerythrin (PE). The lymphocyte subset of interest is selected using CD4, CD8, or CD19 energy-coupled dye (ECD) labeling. Apoptosis is detected using Annexin V-FITC with 7-amino-Actinomycin-D (7-AAD) to distinguish early apoptotic from late apoptotic lymphocytes. RESULTS: We have developed a new technique to detect apoptosis in isolated human peripheral blood lymphocyte subsets with good reproducibility, coefficient of variation < 17%. CONCLUSIONS: We now have a validated tool to study apoptosis in subsets of isolated human lymphocytes to increase our knowledge of pathogenesis and therapies in lymphoreticular malignancies. Copyright 2000 Wiley-Liss, Inc.
BACKGROUND:Human peripheral blood lymphocytes kept in culture after isolation die by an apoptotic process. Detection of apoptosis with labeled Annexin V to demonstrate loss of plasma membrane asymmetry is sensitive, specific, and easy using flow cytometry. This is true in lymphoblastic cell lines when combining Annexin V-fluorescein isothiocyanate (FITC) and propidium iodide (PI). However, measurement of apoptosis by flow cytometry in isolated human lymphocytes using Annexin V-FITC/PI is disturbed by the presence of a variable percentage of erythrocytes in the isolated lymphocyte population. To overcome this problem, we have developed and tested a new four-color flow cytometric assay to detect apoptosis in lymphocyte subsets of cultured peripheral blood cells. METHODS: Peripheral blood lymphocytes are isolated by density gradient centrifugation. Nucleus-containing cells are selected using CD45-phycoerythrin (PE). The lymphocyte subset of interest is selected using CD4, CD8, or CD19 energy-coupled dye (ECD) labeling. Apoptosis is detected using Annexin V-FITC with 7-amino-Actinomycin-D (7-AAD) to distinguish early apoptotic from late apoptotic lymphocytes. RESULTS: We have developed a new technique to detect apoptosis in isolated human peripheral blood lymphocyte subsets with good reproducibility, coefficient of variation < 17%. CONCLUSIONS: We now have a validated tool to study apoptosis in subsets of isolated human lymphocytes to increase our knowledge of pathogenesis and therapies in lymphoreticular malignancies. Copyright 2000 Wiley-Liss, Inc.
Authors: Srikanth Yellayi; Afia Naaz; Melissa A Szewczykowski; Tomomi Sato; Jeffrey A Woods; Jongsoo Chang; Mariangela Segre; Clint D Allred; William G Helferich; Paul S Cooke Journal: Proc Natl Acad Sci U S A Date: 2002-05-28 Impact factor: 11.205
Authors: Malgorzata Czystowska; William Gooding; Miroslaw J Szczepanski; Andres Lopez-Abaitero; Robert L Ferris; Jonas T Johnson; Theresa L Whiteside Journal: Clin Cancer Res Date: 2012-12-19 Impact factor: 12.531
Authors: Pedro Costa Del Amo; Bisrat Debebe; Milad Razavi-Mohseni; Shinji Nakaoka; Andrew Worth; Diana Wallace; Peter Beverley; Derek Macallan; Becca Asquith Journal: Front Immunol Date: 2020-04-08 Impact factor: 7.561