Literature DB >> 10802998

The effect of full protective gear on intubation performance by hospital medical personnel.

I Hendler1, O Nahtomi, E Segal, A Perel, M Wiener, J Meyerovitch.   

Abstract

OBJECTIVE: To assess the influence of protective gear on intubation performance.
DESIGN: Prospective, controlled measurement of duration and quality of intubations performed on mannequins by medical personnel with and without protective gear in a crossover design. PARTICIPANTS: Eight teams each comprising an anesthesiologist and a nurse.
RESULTS: Intubation duration with and without chemical warfare gear was 69.2 +/- 7 and 47.3 +/- 6 seconds (mean +/- SEM), respectively (p < 0.05). Moreover, rating of intubation quality as "very good" by the anesthesiologists declined significantly from 62.5% without chemical warfare protective gear to 6.25% with the garment and mask. Tube fixation was the rate-limiting step when performed with protective gear (p < 0.05); it was assessed by 81% of the anesthesiologists as the critical step. A learning curve was not observed during the study.
CONCLUSION: Protective gear causes a significant prolongation of intubation duration; however, endotracheal intubation can be performed effectively. Technical improvements are warranted for tube fixation because it is the critical step.

Entities:  

Mesh:

Year:  2000        PMID: 10802998

Source DB:  PubMed          Journal:  Mil Med        ISSN: 0026-4075            Impact factor:   1.437


  4 in total

1.  Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.

Authors:  Jos H Verbeek; Blair Rajamaki; Sharea Ijaz; Christina Tikka; Jani H Ruotsalainen; Michael B Edmond; Riitta Sauni; F Selcen Kilinc Balci
Journal:  Cochrane Database Syst Rev       Date:  2019-07-01

Review 2.  Graphene Modified Multifunctional Personal Protective Clothing.

Authors:  Shovon Bhattacharjee; Rakesh Joshi; Abrar Ahmad Chughtai; Chandini Raina Macintyre
Journal:  Adv Mater Interfaces       Date:  2019-08-20       Impact factor: 6.147

3.  Personal protection equipment for biological hazards: does it affect tracheal intubation performance?

Authors:  K B Greenland; D Tsui; P Goodyear; M G Irwin
Journal:  Resuscitation       Date:  2007-03-13       Impact factor: 5.262

4.  Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.

Authors:  Jos H Verbeek; Blair Rajamaki; Sharea Ijaz; Riitta Sauni; Elaine Toomey; Bronagh Blackwood; Christina Tikka; Jani H Ruotsalainen; F Selcen Kilinc Balci
Journal:  Cochrane Database Syst Rev       Date:  2020-04-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.