Literature DB >> 10800039

Correction for acceleration-induced displacement artifacts in phase contrast imaging.

P Thunberg1, L Wigström, B Wranne, J Engvall, M Karlsson.   

Abstract

The acceleration-induced displacement artifact impairs the accuracy of MR velocity measurements. This study proposes a post processing method for correction of this artifact. Velocity measurements were performed in a flow phantom containing a constriction. Velocity curves were obtained from streamlines parallel to the frequency, phase, and slice directions, respectively. The acceleration-induced displacement artifact was most prominent when the frequency encoding direction was aligned with the flow direction. After correction, velocity assignment improved and a more accurate description of the flow was obtained. In vivo measurements were performed in the aorta in a patient with a repaired aortic coarctation. The correction method was applied to velocity data along a streamline parallel to the frequency encoding direction. The result after correction was a new location of the peak velocity and improved estimates of the velocity gradients. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 10800039     DOI: 10.1002/(sici)1522-2594(200005)43:5<734::aid-mrm16>3.0.co;2-a

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

2.  Virtual injections using 4D flow MRI with displacement corrections and constrained probabilistic streamlines.

Authors:  Grant S Roberts; Michael W Loecher; Alma Spahic; Kevin M Johnson; Patrick A Turski; Laura B Eisenmenger; Oliver Wieben
Journal:  Magn Reson Med       Date:  2021-12-31       Impact factor: 4.668

3.  Quantitative time-of-flight MR angiography for simultaneous luminal and hemodynamic evaluation of the intracranial arteries.

Authors:  Ioannis Koktzoglou; Rong Huang; Robert R Edelman
Journal:  Magn Reson Med       Date:  2021-08-10       Impact factor: 4.668

4.  Numerical simulation of time-resolved 3D phase-contrast magnetic resonance imaging.

Authors:  Thomas Puiseux; Anou Sewonu; Ramiro Moreno; Simon Mendez; Franck Nicoud
Journal:  PLoS One       Date:  2021-03-26       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.