Literature DB >> 10799440

Inconsistencies in sweat testing in UK laboratories.

J M Kirk1.   

Abstract

BACKGROUND: Sweat testing procedures are perceived to vary widely. AIM: To evaluate variability in sweat collection, analysis, and interpretation.
METHODS: Questionnaire responses from 30 self selected centres: 15 paediatric centres, and 15 district general hospitals.
RESULTS: Centres carried out 30-400 tests per year (median 100), with a diagnostic rate of 1:5-152 (median 1:30). Staff performed 5-268 tests per year. Minimum test age varied from 24 hours to four months. All stimulated sweating by pilocarpine iontophoresis using varying currents and times. Twenty six had observed urticaria or skin reddening, and nine blistering or burns. Sweat was collected for 10-60 minutes onto filter paper or into Macroduct coils. Between 2% and 25% of tests were considered insufficient. Twenty eight measured sodium, 24 chloride, and one osmolality and conductivity. Fifteen used literature and five in house reference ranges. Eleven would not test severely eczematous children.
CONCLUSIONS: Local audit is required to improve performance, as well as a national guideline to standardise collection, and external quality assessment to provide analytical feedback.

Entities:  

Mesh:

Year:  2000        PMID: 10799440      PMCID: PMC1718298          DOI: 10.1136/adc.82.5.425

Source DB:  PubMed          Journal:  Arch Dis Child        ISSN: 0003-9888            Impact factor:   3.791


  5 in total

1.  A test for concentration of electrolytes in sweat in cystic fibrosis of the pancreas utilizing pilocarpine by iontophoresis.

Authors:  L E GIBSON; R E COOKE
Journal:  Pediatrics       Date:  1959-03       Impact factor: 7.124

2.  Is the sweat test safe? Some instances of burns received during pilocarpine iontophoresis.

Authors:  J M Rattenbury; E Worthy
Journal:  Ann Clin Biochem       Date:  1996-09       Impact factor: 2.057

3.  Neonatal screening for cystic fibrosis in the Trent region (UK): two-stage immunoreactive trypsin screening compared with a three-stage protocol with DNA analysis as an intermediate step.

Authors:  R J Pollitt; A Dalton; S Evans; H N Hughes; D Curtis
Journal:  J Med Screen       Date:  1997       Impact factor: 2.136

4.  Sweat tests and flucloxacillin.

Authors:  J Williams; P D Griffiths; A Green; P H Weller
Journal:  Arch Dis Child       Date:  1988-07       Impact factor: 3.791

5.  Mild cystic fibrosis and normal or borderline sweat test in patients with the 3849 + 10 kb C-->T mutation.

Authors:  A Augarten; B S Kerem; Y Yahav; S Noiman; Y Rivlin; A Tal; H Blau; L Ben-Tur; A Szeinberg; E Kerem
Journal:  Lancet       Date:  1993-07-03       Impact factor: 79.321

  5 in total
  5 in total

1.  Sweat test and cystic fibrosis: overview of test performance at public and private centers in the state of São Paulo, Brazil.

Authors:  Maria Fátima Servidoni; Carla Cristina Souza Gomez; Fernando Augusto Lima Marson; Adyléia Aparecida Dalbo Contrera Toro; Maria Ângela Gonçalves de Oliveira Ribeiro; José Dirceu Ribeiro; Antônio Fernando Ribeiro
Journal:  J Bras Pneumol       Date:  2017 Mar-Apr       Impact factor: 2.624

2.  Evaluation of continuous constant current and continuous pulsed current in sweat induction for cystic fibrosis diagnosis.

Authors:  Carla Cristina Souza Gomez; Fernando Augusto Lima Marson; Maria Fátima Servidoni; Antônio Fernando Ribeiro; Maria Ângela Gonçalves Oliveira Ribeiro; Veruska Acioli Lopes Gama; Eduardo Tavares Costa; José Dirceu Ribeiro; Francisco Ubaldo Vieira Junior
Journal:  BMC Pulm Med       Date:  2018-09-14       Impact factor: 3.317

3.  Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management.

Authors:  Tyler R Ray; Maja Ivanovic; Paul M Curtis; Daniel Franklin; Kerem Guventurk; William J Jeang; Joseph Chafetz; Hannah Gaertner; Grace Young; Steve Rebollo; Jeffrey B Model; Stephen P Lee; John Ciraldo; Jonathan T Reeder; Aurélie Hourlier-Fargette; Amay J Bandodkar; Jungil Choi; Alexander J Aranyosi; Roozbeh Ghaffari; Susanna A McColley; Shannon Haymond; John A Rogers
Journal:  Sci Transl Med       Date:  2021-03-31       Impact factor: 17.956

4.  Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

Authors:  Carla Cristina Souza Gomez; Maria de Fatima Servidoni; Fernando Augusto de Lima Marson; Paulo Jose Coelho Canavezi; Adriana Mendes Vinagre; Eduardo Tavares Costa; Antonio Fernando Ribeiro; Maria Angela Gonçalves de Oliveira Ribeiro; Adyleia Aparecida Dalbo Contrera Toro; Celia Regina Pavan; Michelle Vivine Sá Dos Santos Rondon; Sonia Leticia Silva Lorena; Francisco Ubaldi Vieria; Jose Dirceu Ribeiro
Journal:  BMC Pulm Med       Date:  2014-12-13       Impact factor: 3.317

5.  The Italian External Quality Assessment Program for Cystic Fibrosis Sweat Chloride Test: Does Active Participation Improve the Quality?

Authors:  Marco Salvatore; Annalisa Amato; Giovanna Floridia; Federica Censi; Gianluca Ferrari; Fabrizio Tosto; Rita Padoan; Valeria Raia; Natalia Cirilli; Giuseppe Castaldo; Ettore Capoluongo; Ubaldo Caruso; Carlo Corbetta; Domenica Taruscio
Journal:  Int J Environ Res Public Health       Date:  2020-05-04       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.