Goldmann applanation versus hand-applanation and .schiötz indentation tonometry.

G K Krieglstein, W K Waller.   

Abstract

For evaluation of hand-applanation tonometry comparative measurements of intraocular pressure have been carried out using the Goldmann applanation tonometer, the Draeger and Perkins hand-applanation tonometers and the Schiötz indentation tonometer. A series of 52 eyes has been tested. The statistical analysis was based on the Goldmann tonometry as a reference system. The hand-applanation tonometers were found to be in satisfactory agreement with the Goldmann tonometer, whereas the Schiötz tonometer gave significantly low values in the pressure range considered.

Mesh:

Year:  1975        PMID: 1079117     DOI: 10.1007/bf00408271

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  10 in total

1.  APPLANATION VERSUS SCHIOTZ TONOMETRY: THE SYNDROME OF "REVERSE OCULAR RIGIDITY".

Authors:  J L SMITH
Journal:  Am J Ophthalmol       Date:  1964-11       Impact factor: 5.258

2.  Comparison of Schiötz and Goldmann tonometry in a population.

Authors:  B Bengtsson
Journal:  Acta Ophthalmol (Copenh)       Date:  1972

3.  Perkins applanation tonometer. Clinical and laboratory evaluation.

Authors:  J S Dunn; R F Brubaker
Journal:  Arch Ophthalmol       Date:  1973-02

4.  Perkins hand-held applanation tonometer. A clinical evaluation.

Authors:  J Wallace; H G Lovell
Journal:  Br J Ophthalmol       Date:  1968-07       Impact factor: 4.638

5.  Hand-held applanation tonometer.

Authors:  E S Perkins
Journal:  Br J Ophthalmol       Date:  1965-11       Impact factor: 4.638

6.  On repeated tonometry.

Authors:  C E Krakau; K Wilke
Journal:  Acta Ophthalmol (Copenh)       Date:  1971

7.  Principle and clinical application of a portable applanation tonometer.

Authors:  J Draeger
Journal:  Invest Ophthalmol       Date:  1967-04

8.  [On a position-independent applanation tonometer].

Authors:  J Draeger
Journal:  Klin Monbl Augenheilkd       Date:  1966       Impact factor: 0.700

9.  On tonometry. 6. Comparative tonometry with the Goldmann applanation tonometer and the Schiötz tonometer in the lying position.

Authors:  J Hetland-Eriksen
Journal:  Acta Ophthalmol (Copenh)       Date:  1966

10.  The incidence of Schiøtz-applanation disparity.

Authors: 
Journal:  Arch Ophthalmol       Date:  1967-03
  10 in total
  7 in total

1.  Screening tonometry by technicians.

Authors:  G K Krieglstein
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1975

2.  [Mobile intraocular pressure measurement. From palpation to initial clinical experience with the handheld dynamic contour tonometer].

Authors:  U Schmid; C Kniestedt
Journal:  Ophthalmologe       Date:  2010-07       Impact factor: 1.059

3.  [Comparative intraocular pressure measurements with position independent hand-applanatation tonometers (author's transl)].

Authors:  G K Kreiglstein; V Brethfeld; E von Collani
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1976-04-14

4.  Evaluation of intra ocular pressure in zygomatico maxillary complex fractures.

Authors:  Rohit Sharma; Naveen Chhabra; Parveen Sharma; Shruti Chhabra
Journal:  J Maxillofac Oral Surg       Date:  2014-01-10

5.  Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods.

Authors:  R Arora; H Bellamy; Mw Austin
Journal:  Clin Ophthalmol       Date:  2014-03-26

6.  Diurnal variation in central corneal thickness and intraocular pressure in eyes with pseudoexfoliation syndrome without glaucoma.

Authors:  Stuart Keel; Linda Malesic; Siew-Pang Chan
Journal:  Indian J Ophthalmol       Date:  2014-11       Impact factor: 1.848

7.  Comparative evaluation of applanation and indentation tonometers in a community ophthalmology setting in Southern India.

Authors:  Swathi Nagarajan; Veerabahu Velayutham; G Ezhumalai
Journal:  Saudi J Ophthalmol       Date:  2015-11-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.