Literature DB >> 10789807

Single breath-hold T2-weighted MR imaging of the liver: value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging.

M Hori1, T Murakami, T Kim, M Kanematsu, K Tsuda, S Takahashi, M Takamura, H Hoshi, H Nakamura.   

Abstract

OBJECTIVE: The objective of our study was to evaluate the efficacy of single breath-hold T2-weighted MR imaging for detection of focal hepatic lesions.
MATERIALS AND METHODS: T2-weighted MR images were retrospectively reviewed from 51 patients with 85 solid and 59 nonsolid lesions using the following four sequences: conventional spin-echo, respiratory-triggered fast spin-echo, single-shot fast spin-echo, and multishot spin-echo echoplanar imaging. Images were reviewed on a hepatic segment-by-segment basis; T2-weighted images of a total of 408 hepatic segments were reviewed separately and independently for solid and nonsolid lesions by four radiologists. Quantitative, qualitative, and receiver operating characteristic analyses were performed.
RESULTS: For solid lesions, no significant differences were seen among the lesion-to-liver contrast-to-noise ratios with the four sequences. In terms of solid lesion detection, no significant difference was seen between the diagnostic accuracy of multishot spin-echo echoplanar (Az = 0.90) and respiratory-triggered fast spin-echo (Az = 0.91) imaging, which showed the best performance of the four sequences. For nonsolid lesion detection, respiratory-triggered fast spin-echo and single-shot fast spin-echo imaging were judged the best (Az = 0.94).
CONCLUSION: Breath-hold single-shot fast spin-echo and multishot spin-echo echoplanar sequences can be substituted for conventional spin-echo and respiratory-triggered fast spin-echo T2-weighted sequences.

Entities:  

Mesh:

Year:  2000        PMID: 10789807     DOI: 10.2214/ajr.174.5.1741423

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  Comparison of diffusion-weighted imaging and T2-weighted single shot fast spin-echo: Implications for LI-RADS characterization of hepatocellular carcinoma.

Authors:  Robert M Hicks; Judy Yee; Michael A Ohliger; Stefanie Weinstein; Jeffrey Kao; Nabia S Ikram; Thomas A Hope
Journal:  Magn Reson Imaging       Date:  2016-04-21       Impact factor: 2.546

2.  Synchronisation strategies in T2-weighted MR imaging for detection of liver lesions: Application on a nude mouse model.

Authors:  L Baboi; L Milot; C Lartizien; C Roche; J-Y Scoazec; F Pilleul; O Beuf
Journal:  Biomed Imaging Interv J       Date:  2007-10-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.