Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations.

I Kawrakow1.   

Abstract

In this report the condensed history Monte Carlo simulation of electron transport and its application to the calculation of ion chamber response is discussed. It is shown that the strong step-size dependencies and lack of convergence to the correct answer previously observed are the combined effect of the following artifacts caused by the EGS4/PRESTA implementation of the condensed history technique: dose underprediction due to PRESTA'S pathlength correction and lateral correlation algorithm; dose overprediction due to the boundary crossing algorithm; dose overprediction due to the breakdown of the fictitious cross section method for sampling distances between discrete interaction and the inaccurate evaluation of energy-dependent quantities. These artifacts are now understood quantitatively and analytical expressions for their effect are given.

Mesh:

Year:  2000        PMID: 10757602     DOI: 10.1118/1.598918

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  The perturbation correction factors for cylindrical ionization chambers in high-energy photon beams.

Authors:  Fumiaki Yoshiyama; Fujio Araki; Takeshi Ono
Journal:  Radiol Phys Technol       Date:  2010-04-22

2.  Use of calculations to validate beam quality and relative dose measurements for a kilovoltage X-ray therapy unit.

Authors:  B J Healy; R F Hill
Journal:  Phys Eng Sci Med       Date:  2022-04-05

3.  Comparative dosimetry of GammaMed Plus high-dose rate Ir brachytherapy source.

Authors:  N P Patel; B Majumdar; V Vijayan
Journal:  J Med Phys       Date:  2010-07

4.  A method to improve accuracy and precision of water surface identification for photon depth dose measurements.

Authors:  J D Ververs; M J Schaefer; I Kawrakow; J V Siebers
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

5.  Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group.

Authors:  P Arce; D Bolst; M-C Bordage; J M C Brown; P Cirrone; M A Cortés-Giraldo; D Cutajar; G Cuttone; L Desorgher; P Dondero; A Dotti; B Faddegon; C Fedon; S Guatelli; S Incerti; V Ivanchenko; D Konstantinov; I Kyriakou; G Latyshev; A Le; C Mancini-Terracciano; M Maire; A Mantero; M Novak; C Omachi; L Pandola; A Perales; Y Perrot; G Petringa; J M Quesada; J Ramos-Méndez; F Romano; A B Rosenfeld; L G Sarmiento; D Sakata; T Sasaki; I Sechopoulos; E C Simpson; T Toshito; D H Wright
Journal:  Med Phys       Date:  2020-12-12       Impact factor: 4.071

6.  GPU-accelerated Monte Carlo simulation of MV-CBCT.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Dianne Ferguson; Christopher Williams; Mathias Lehmann; Paul Baturin; Pascal Huber; Rony Fueglistaller; Ingrid Valencia Lozano; Thomas Harris; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 4.174

7.  Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening-filter-free 7 MV beam line.

Authors:  Alemeh Sadrollahi; Frank Nuesken; Norbert Licht; Christian Rübe; Yvonne Dzierma
Journal:  PLoS One       Date:  2019-01-08       Impact factor: 3.240

8.  Comparison of penh, fluka, and Geant4/topas for absorbed dose calculations in air cavities representing ionization chambers in high-energy photon and proton beams.

Authors:  Kilian-Simon Baumann; Felix Horst; Klemens Zink; Carles Gomà
Journal:  Med Phys       Date:  2019-08-19       Impact factor: 4.071

9.  Step-size effect on calculated photon and electron beam Cherenkov-to-dose conversion factors.

Authors:  Yana Zlateva; Bryan R Muir; Issam El Naqa; Jan Seuntjens
Journal:  Phys Med       Date:  2020-09-08       Impact factor: 2.685

10.  Effect of dental restorations and prostheses on radiotherapy dose distribution: a Monte Carlo study.

Authors:  David W H Chin; Nathaniel Treister; Bernard Friedland; Robert A Cormack; Roy B Tishler; G Mike Makrigiorgos; Laurence E Court
Journal:  J Appl Clin Med Phys       Date:  2009-02-03       Impact factor: 2.102

  10 in total