The effect of dose calculation uncertainty on the evaluation of radiotherapy plans.

P J Keall1, J V Siebers, R Jeraj, R Mohan.   

Abstract

Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our purpose in this study was to determine the level of uncertainty at which a lung treatment plan is clinically acceptable. The evaluation methods to decide acceptability were visual examination of both isodose lines on CT scans and dose volume histograms (DVHs), and reviewing calculated biological indices. To study the effect of systematic and/or random errors on treatment plan evaluation, a simulated "error-free" reference plan was used as a benchmark. The relationship between Monte Carlo statistical uncertainty and dose was found to be approximately proportional to the square root of the dose. Random and systematic errors were applied to a calculated lung plan, creating dose distributions with statistical uncertainties of between 0% and 16% (1 s.d.) at the maximum dose point and also distributions with systematic errors of -16% to 16% at the maximum dose point. Critical structure DVHs and biological indices are less sensitive to calculation uncertainty than those of the target. Systematic errors affect plan evaluation accuracy significantly more than random errors, suggesting that Monte Carlo dose calculation will improve outcomes in radiotherapy. A statistical uncertainty of 2% or less does not significantly affect isodose lines, DVHs, or biological indices.

Mesh:

Year:  2000        PMID: 10757600     DOI: 10.1118/1.598916

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom.

Authors:  Alireza Farajollahi; Asghar Mesbahi
Journal:  Radiat Med       Date:  2006-05

2.  Assessment of dose reconstruction errors in image-guided radiation therapy.

Authors:  Hualiang Zhong; Elisabeth Weiss; Jeffrey V Siebers
Journal:  Phys Med Biol       Date:  2008-01-11       Impact factor: 3.609

3.  Concurrent Monte Carlo transport and fluence optimization with fluence adjusting scalable transport Monte Carlo.

Authors:  Y M Yang; M Svatos; C Zankowski; B Bednarz
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

4.  The effect of statistical noise on IMRT plan quality and convergence for MC-based and MC-correction-based optimized treatment plans.

Authors:  Jeffrey V Siebers
Journal:  J Phys Conf Ser       Date:  2008-04-04

5.  Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases.

Authors:  Mohandass Palanisamy; Khanna David; Manigandan Durai; Narendra Bhalla; Abhishek Puri
Journal:  Rep Pract Oncol Radiother       Date:  2019-02-18

6.  Moving GPU-OpenCL-based Monte Carlo dose calculation toward clinical use: Automatic beam commissioning and source sampling for treatment plan dose calculation.

Authors:  Zhen Tian; Yongbao Li; Nima Hassan-Rezaeian; Steve B Jiang; Xun Jia
Journal:  J Appl Clin Med Phys       Date:  2017-02-16       Impact factor: 2.102

7.  Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system.

Authors:  M Miften; M Wiesmeyer; A Kapur; C M Ma
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

8.  Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy.

Authors:  Nesrin Dogan; Ivaylo Mihaylov; Yan Wu; Paul J Keall; Jeffrey V Siebers; Michael P Hagan
Journal:  Radiat Oncol       Date:  2009-06-15       Impact factor: 3.481

9.  Effects of spatial resolution and noise on gamma analysis for IMRT QA.

Authors:  Jessie Y Huang; Kiley B Pulliam; Elizabeth M McKenzie; David S Followill; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

10.  Validation of a Software Upgrade in a Monte Carlo Treatment Planning System by Comparison of Plans in Different Versions.

Authors:  P Mohandass; D Khanna; D Manigandan; Narendra Kumar Bhalla; Abhishek Puri
Journal:  J Med Phys       Date:  2018 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.