Literature DB >> 10757598

Direct measurement and analytical modeling of scatter in portal imaging.

L Spies1, P M Evans, M Partridge, V N Hansen, T Bortfeld.   

Abstract

In this study a direct measurement of scatter in portal imaging for various air gaps and scatterer thicknesses at a beam energy of 6 MV is presented. The experimental data are compared with results from a Monte Carlo (MC) scatter model. In the regime where the air gap is larger than 9.3 cm the MC and the experiment agree. Based on this MC model an analytical model is developed, which takes all important interaction processes into account. It comprises a rigorous treatment of first order scattering and an estimation of photons scattered more than once within the phantom. This estimation is based on the assumption that higher order scattering can be considered as isotropically distributed around a certain scatter origin located in the midplane of the phantom. It is found that relative deviations between the MC model and the analytical model are of 2% to 3% in regions where scattering is very large.

Mesh:

Year:  2000        PMID: 10757598     DOI: 10.1118/1.598914

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Numerical deconvolution to enhance sharpness and contrast of portal images for radiotherapy patient positioning verification.

Authors:  H K Looe; Y Uphoff; D Harder; B Poppe; K C Willborn
Journal:  Strahlenther Onkol       Date:  2012-01-12       Impact factor: 3.621

2.  Evaluation of a cone beam CT artefact reduction algorithm.

Authors:  B Bechara; C A McMahan; H Geha; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-02-23       Impact factor: 2.419

Review 3.  Bone mineral density in cone beam computed tomography: Only a few shades of gray.

Authors:  Marcio José da Silva Campos; Thainara Salgueiro de Souza; Sergio Luiz Mota Júnior; Marcelo Reis Fraga; Robert Willer Farinazzo Vitral
Journal:  World J Radiol       Date:  2014-08-28

4.  Library based x-ray scatter correction for dedicated cone beam breast CT.

Authors:  Linxi Shi; Srinivasan Vedantham; Andrew Karellas; Lei Zhu
Journal:  Med Phys       Date:  2016-08       Impact factor: 4.071

5.  Optimization of the geometry and speed of a moving blocker system for cone-beam computed tomography scatter correction.

Authors:  Xi Chen; Luo Ouyang; Hao Yan; Xun Jia; Bin Li; Qingwen Lyu; You Zhang; Jing Wang
Journal:  Med Phys       Date:  2017-09       Impact factor: 4.071

6.  Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

Authors:  Stephen Brunner; Brian E Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2011-01-21       Impact factor: 3.609

7.  Shading correction for volumetric CT using deep convolutional neural network and adaptive filter.

Authors:  Xiaokun Liang; Na Li; Zhicheng Zhang; Shaode Yu; Wenjian Qin; Yafen Li; Shupeng Chen; Huailing Zhang; Yaoqin Xie
Journal:  Quant Imaging Med Surg       Date:  2019-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.