STATEMENT OF PROBLEM: All-ceramic crowns are being used extensively. Little data are available on their clinical performance.
PURPOSE: This study evaluated the clinical performance of In-Ceram (Vita Zahnfabrik) crowns.
MATERIAL AND METHODS: Forty-one patients (16 men, 25 women; mean age 47.3 years, range 18 to 77 years) were examined with a total of 80 In-Ceram all-ceramic crowns fabricated at the University of Iowa College of Dentistry from 1994 to 1997. The percentage distribution for crowns included: 67% anterior single crowns, 26% posterior single crowns, 6% anterior implant crowns, and 1% posterior implant crowns. This study documented the integrity of the junction between crown and tooth, color match to adjacent teeth, secondary dental caries, wear of crown and opposing dentition, and visible cracks in the crown. Alpha, Bravo, and Charlie ratings were assigned with a modified USPHS criteria. The patients were also surveyed with respect to oral hygiene and satisfaction of treatment. Estimations of 4-year success rates and corresponding confidence intervals were calculated by fitting a constant hazard function model with the SAS procedure GENMOD.
RESULTS: Marginal integrity for 88% of artificial crowns was rated Alpha or Bravo. Shade match for 99% was Bravo or better. Only 1% of the crowns were carious, and 1 crown exhibited occlusal wear. One premolar crown had a small fracture of veneering porcelain. One molar crown was remade after core fracture. All patients (100%) expressed satisfaction with their crowns. The estimated 4-year success rates (Alpha or Bravo), with 95% confidence intervals in parentheses were calculated as: 83.5% (65.7%-94.6%) for marginal integrity, 95.8% (82.9%-99.8%) for shade match, and 95.5% (81.6%-99.7%) for secondary caries, 100% (88%-100%) for wear, and 100% (88%-100%) for cracks.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10756288     DOI: 10.1016/s0022-3913(00)70033-3

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  20 in total

1.  Effect of sandblasting, silica coating, and laser treatment on the microtensile bond strength of a dental zirconia ceramic to resin cements.

Authors:  Nasrin Mahmoodi; Tabassom Hooshmand; Solmaz Heidari; Kimia Khoshro
Journal:  Lasers Med Sci       Date:  2015-12-21       Impact factor: 3.161

2.  Stress intensity factor threshold in dental porcelains.

Authors:  Humberto Naoyuki Yoshimura; Paulo Francisco Cesar; Fabiana Naomi Soki; Carla Castiglia Gonzaga
Journal:  J Mater Sci Mater Med       Date:  2007-10-18       Impact factor: 3.896

3.  Measurement of color for craniofacial structures using a 45/0-degree optical configuration.

Authors:  David J Gozalo-Diaz; Delwin T Lindsey; William M Johnston; Alvin G Wee
Journal:  J Prosthet Dent       Date:  2007-01       Impact factor: 3.426

4.  Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns.

Authors:  Kallaya Suputtamongkol; Kenneth J Anusavice; Chatcharee Suchatlampong; Phira Sithiamnuai; Chantana Tulapornchai
Journal:  Dent Mater       Date:  2007-08-28       Impact factor: 5.304

5.  Influence of CAD/CAM all-ceramic materials on cell viability, migration ability and adenylate kinase release of human gingival fibroblasts and oral keratinocytes.

Authors:  A M Pabst; C Walter; L Grassmann; M Weyhrauch; D D Brüllmann; T Ziebart; H Scheller; K M Lehmann
Journal:  Clin Oral Investig       Date:  2013-08-31       Impact factor: 3.573

6.  Long-term performance of posterior InCeram Alumina crowns cemented with different luting agents: a prospective, randomized clinical split-mouth study over 5 years.

Authors:  Christian F Selz; Joerg R Strub; Kirstin Vach; Petra C Guess
Journal:  Clin Oral Investig       Date:  2013-11-22       Impact factor: 3.573

Review 7.  Ocular prosthesis incorporating IPS e-max press scleral veneer and a literature review on non-integrated ocular prosthesis.

Authors:  Godwin Clovis Da Costa; Meena Ajay Aras; Paul Chalakkal; Michelle Clovis Da Costa
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

8.  Biaxial flexural strength of Turkom-Cera core compared to two other all-ceramic systems.

Authors:  Bandar Mohammed Abdullah Al-Makramani; Abdul Aziz Abdul Razak; Mohamed Ibrahim Abu-Hassan
Journal:  J Appl Oral Sci       Date:  2010-12       Impact factor: 2.698

9.  Characterization of glass-infiltrated alumina-based ceramics.

Authors:  Alvaro Della Bona; John J Mecholsky; Allyson A Barrett; Jason A Griggs
Journal:  Dent Mater       Date:  2008-08-09       Impact factor: 5.304

10.  Use of a porcelain color discrimination test to evaluate color difference formulas.

Authors:  Alvin G Wee; Delwin T Lindsey; Kathryn M Shroyer; William M Johnston
Journal:  J Prosthet Dent       Date:  2007-08       Impact factor: 3.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.