Literature DB >> 10752813

Right atrial pressure predicts hemodynamic response to apneic positive airway pressure.

H Jellinek1, P Krafft, R D Fitzgerald, S Schwarz, M R Pinsky.   

Abstract

OBJECTIVE: To evaluate if the preexistant filling state, assessed by right atrial pressure (RAP), pulmonary artery occlusion pressure (PAOP), and right ventricular end-diastolic volume index (EDVI), would define the subsequent hemodynamic effects of increases in airway pressure (Paw).
DESIGN: Prospective open clinical study.
SETTING: Postoperative intensive care unit, university hospital. PATIENTS: Twenty-two consecutive ventilator-dependent patients with mild to severe acute lung injury with Murray scores (scoring infiltrates on chest radiograph, oxygenation index, lung compliance, and the level of positive end-expiratory pressure) ranging from 0.5 to 3.0 without history of preexisting cardiopulmonary disease.
INTERVENTIONS: Paw varied during apnea from 0 to 10, 20, and 30 cm H2O using inspiratory hold maneuvers of 15 secs.
MEASUREMENTS AND MAIN RESULTS: Cardiac index and right ventricular ejection fraction were measured by the thermodilution technique. We made measurements in triplicate using manual injection of iced saline. Right ventricular volumes were calculated. Increasing Paw induced variable changes in cardiac index among subjects (+6% to -43% change from baseline 0 cm H2O Paw values), which correlated with percentage changes in both stroke index (r2 = .89) and right ventricular EDVI (r2 = .75), whereas heart rate and right ventricular ejection fraction did not change. The change in cardiac index from 0 to 30 cm H2O Paw correlated with baseline values for RAP, PAOP, and right ventricular EDVI (r2 = .68, .43, and .34, respectively, p < 0.01). Increases in RAP correlated with lung compliance if baseline RAP was >10 mm Hg but did not if it was < or =10 mm Hg. Similarly, patients with baseline RAP < or =10 mm Hg had a greater decrease in cardiac index than patients with a RAP >10 mm Hg (for 30 cm H2O Paw: -30% +/- 9% vs. -8% +/- 7%, p < .01).
CONCLUSIONS: Apneic positive Paw decreased cardiac output mainly by reducing venous return. From the investigated filling variables, RAP was most sensitive in predicting the hemodynamic response, followed by PAOP and right ventricular EDVI. Patients with RAP < or =10 mm Hg, if subjected to aggressive positive pressure ventilation, are at risk of hemodynamic deterioration and organ hypoperfusion.

Entities:  

Mesh:

Year:  2000        PMID: 10752813     DOI: 10.1097/00003246-200003000-00012

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  11 in total

Review 1.  Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care.

Authors:  Karim Bendjelid; Jacques-A Romand
Journal:  Intensive Care Med       Date:  2003-01-21       Impact factor: 17.440

Review 2.  Right ventricular function and positive pressure ventilation in clinical practice: from hemodynamic subsets to respirator settings.

Authors:  François Jardin; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2003-08-09       Impact factor: 17.440

Review 3.  Effects of peep on lung injury, pulmonary function, systemic circulation and mortality in animals with uninjured lungs-a systematic review.

Authors:  Anna Geke Algera; Luigi Pisani; Renato Carneiro de Freitas Chaves; Thiago Chaves Amorim; Thomas Cherpanath; Rogier Determann; Dave A Dongelmans; Frederique Paulus; Pieter Roel Tuinman; Paolo Pelosi; Marcelo Gama de Abreu; Marcus J Schultz; Ary Serpa Neto
Journal:  Ann Transl Med       Date:  2018-01

Review 4.  Functional hemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Crit Care Clin       Date:  2015-01       Impact factor: 3.598

5.  Smart Bag vs. Standard bag in the temporary substitution of the mechanical ventilation.

Authors:  Robin Lovat; Christine Watremez; Michel Van Dyck; Olivier Van Caenegem; Franck Verschuren; Philippe Hantson; Luc-Marie Jacquet
Journal:  Intensive Care Med       Date:  2007-10-10       Impact factor: 17.440

6.  Right atrial pressure affects the interaction between lung mechanics and right ventricular function in spontaneously breathing COPD patients.

Authors:  Bart Boerrigter; Pia Trip; Harm Jan Bogaard; Herman Groepenhoff; Frank Oosterveer; Nico Westerhof; Anton Vonk Noordegraaf
Journal:  PLoS One       Date:  2012-01-17       Impact factor: 3.240

Review 7.  Clinical review: Positive end-expiratory pressure and cardiac output.

Authors:  Thomas Luecke; Paolo Pelosi
Journal:  Crit Care       Date:  2005-10-18       Impact factor: 9.097

Review 8.  Functional hemodynamic monitoring.

Authors:  Michael R Pinsky; Didier Payen
Journal:  Crit Care       Date:  2005-11-22       Impact factor: 9.097

Review 9.  PEEP role in ICU and operating room: from pathophysiology to clinical practice.

Authors:  M Vargas; Y Sutherasan; C Gregoretti; P Pelosi
Journal:  ScientificWorldJournal       Date:  2014-01-14

10.  Single Minute of Positive End-expiratory Pressure at the Time of Induction: Effect on Arterial Blood Gases and Hemodynamics in Morbidly Obese Patients Undergoing Laparoscopic Bariatric Surgery.

Authors:  Dipti Saxena; Priyank Singh; Atul Dixit; Bipin Arya; Mohit Bhandari; Sadhana Sanwatsarkar
Journal:  Anesth Essays Res       Date:  2017 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.