Literature DB >> 10743781

Nonlinear adaptive filtering of stimulus artifact.

R Grieve1, P A Parker, B Hudgins, K Englehart.   

Abstract

Noninvasive measurements of somatosensory evoked potentials have both clinical and research applications. The electrical artifact which results from the stimulus is an interference which can distort the evoked signal, and introduce errors in response onset timing estimation. Given that this interference is synchronous with the evoked signal, it cannot be reduced by the conventional technique of ensemble averaging. The technique of adaptive noise cancelling has potential in this regard however, and has been used effectively in other similar problems. An adaptive noise cancelling filter which uses a neural network as the adaptive element is investigated in this application. The filter is implemented and performance determined in the cancelling of artifact for in vivo measurements on the median nerve. A technique of segmented neural network training is proposed in which the network is trained on that segment of the record time window which does not contain the evoked signal. The neural network is found to generalize well from this training to include the segment of the window containing the evoked signal. Both quantitative and qualitative measures show that significant stimulus artifact reduction is achieved.

Mesh:

Year:  2000        PMID: 10743781     DOI: 10.1109/10.827307

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  Real-time ocular artifact suppression using recurrent neural network for electro-encephalogram based brain-computer interface.

Authors:  A Erfanian; B Mahmoudi
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

2.  Electrically evoked auditory steady state responses in cochlear implant users.

Authors:  Michael Hofmann; Jan Wouters
Journal:  J Assoc Res Otolaryngol       Date:  2009-12-22

3.  Suppression of stimulus artifact contaminating electrically evoked electromyography.

Authors:  Jie Liu; Sheng Li; Xiaoyan Li; Cliff Klein; William Z Rymer; Ping Zhou
Journal:  NeuroRehabilitation       Date:  2014       Impact factor: 2.138

4.  A retrofitted neural recording system with a novel stimulation IC to monitor early neural responses from a stimulating electrode.

Authors:  Yoonkey Nam; Edgar A Brown; James D Ross; Richard A Blum; Bruce C Wheeler; Stephen P DeWeerth
Journal:  J Neurosci Methods       Date:  2008-11-30       Impact factor: 2.390

5.  Adaptive filtering of evoked potentials using higher-order adaptive signal enhancer with genetic-type variable step-size prefilter.

Authors:  B-S Lin; B-S Lin; F-C Chong; F Lai
Journal:  Med Biol Eng Comput       Date:  2005-09       Impact factor: 3.079

  5 in total