R Draisci1, L Palleschi, E Ferretti, A Furey, K J James, M Satake, T Yasumoto.
Abstract
Azaspiracid is the main toxin responsible for a number of recent human intoxications in Europe resulting from shellfish consumption. The first micro liquid chromatography-tandem mass spectrometry (micro-LC-MS-MS) method was developed for the determination of this novel shellfish poisoning toxin in mussels. The analyte was extracted from whole mussel meat with acetone and chromatographed on a C18 reversed-phase column (1.0 mm I.D.) by isocratic elution at 30 microl/min with acetonitrile-water (85:15, v/v), containing 0.03% trifluoroacetic acid. The toxin was ionised in an ionspray interface operating in the positive ion mode, where only the intact protonated molecule, [M+H]+, was generated at m/z 842. This served as precursor ion for collision-induced dissociation and three product ions, [M+H-nH2O]- with n=1-3, were identified for the unambiguous toxin confirmation by selected reaction monitoring LC-MS-MS analysis. A detection limit of 20 pg, based on a 3:1 signal-to-noise ratio, was achieved for the analyte. This LC-MS-MS method was successfully applied to determine azaspiracid in toxic cultivated shellfish from two regions of Ireland.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10735281 DOI: 10.1016/s0021-9673(99)01023-7
Source DB: PubMed Journal: J Chromatogr A ISSN: 0021-9673 Impact factor: 4.759