Literature DB >> 10725857

Effect of distortions and asymmetry in MR images on radiotherapeutic treatment planning.

F J Prott1, U Haverkamp, H Eich, A Resch, O Micke, A R Fischedick, N Willich, R Pötter.   

Abstract

Before using MR-images for radiotherapeutic treatment planning, it is necessary to check whether geometrical distortions influence the calculated dose distribution. In this study, 27 MRI units from different manufacturers and with different magnetic field strengths were investigated. First, all geometrical distortions and asymmetry were determined by specially defined parameters. Virtual planning target volume and organ of risk were drawn into MR images from different units and optimized dose distributions were calculated. The resulting field parameters were then transferred to the reference geometry. Geometric distortions caused small variations of the dose maximum (+/-0.5%). Twenty-five percent of the investigated calculated dose distributions showed an increase of the 95% isodose volume, 60% a decrease. The dose deviations in the organ of risk were comparable with the dose deviations in the planning target volume (PTV). This study has shown that measurements of geometrical distortions and asymmetry are necessary for MR-assisted treatment planning. For evaluation, we recommend dose calculations with hypothetical PTV's and organs of risk. Int. J. Cancer (Radiat. Oncol. Invest.) 90, 46-50 (2000). Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 10725857

Source DB:  PubMed          Journal:  Int J Cancer        ISSN: 0020-7136            Impact factor:   7.396


  4 in total

1.  Effect of region extraction and assigned mass-density values on the accuracy of dose calculation with magnetic resonance-based volumetric arc therapy planning.

Authors:  Keisuke Usui; Keisuke Sasai; Koichi Ogawa
Journal:  Radiol Phys Technol       Date:  2018-03-14

2.  MRI geometric distortion: Impact on tangential whole-breast IMRT.

Authors:  Amy Walker; Peter Metcalfe; Gary Liney; Vikneswary Batumalai; Kylie Dundas; Carri Glide-Hurst; Geoff P Delaney; Miriam Boxer; Mei Ling Yap; Jason Dowling; David Rivest-Henault; Elise Pogson; Lois Holloway
Journal:  J Appl Clin Med Phys       Date:  2016-09       Impact factor: 2.102

3.  Feasibility and limitations of bulk density assignment in MRI for head and neck IMRT treatment planning.

Authors:  Alexander L Chin; Alexander Lin; Shibu Anamalayil; Boon-Keng Kevin Teo
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

Review 4.  Optimizing MR-Guided Radiotherapy for Breast Cancer Patients.

Authors:  Maureen L Groot Koerkamp; Jeanine E Vasmel; Nicola S Russell; Simona F Shaitelman; Carmel N Anandadas; Adam Currey; Danny Vesprini; Brian M Keller; Chiara De-Colle; Kathy Han; Lior Z Braunstein; Faisal Mahmood; Ebbe L Lorenzen; Marielle E P Philippens; Helena M Verkooijen; Jan J W Lagendijk; Antonetta C Houweling; H J G Desiree van den Bongard; Anna M Kirby
Journal:  Front Oncol       Date:  2020-07-28       Impact factor: 6.244

  4 in total