Application of draft European Commission reference levels to a regional CT dose survey.

J Clarke1, K Cranley, J Robinson, P H Smith, A Workman.   

Abstract

A survey of CT doses in Northern Ireland in the period between October 1995 and March 1997 was carried out. The survey included all but one of the 10 scanners in use at the time, and, additionally, two others that were replacement machines. The method used was to study standard protocols and calculate doses to the NRPB mathematical phantom, so that a direct comparison could be made with other surveys carried out in a similar fashion elsewhere. The survey addressed the patient radiation dose but not image quality or clinical outcomes. It is estimated that in Northern Ireland the contribution to collective dose to the population from CT is about 40% of that from all medical X-rays. The proposed European Commission reference quantities, weighted CT dose index and dose-length product were computed and their potential use evaluated. A full study of mean values of effective dose per examination revealed the average dose per examination was not significantly different from that found in the 1989 UK survey, although several procedures gave rise to doses that were high enough to be investigated with a view to justification or reduction. One of the scanners was found to give consistently high doses. It is likely that a revision of the mAs values used on this scanner will produce a significant reduction in patient doses without compromising image quality. When compared with the draft EC reference levels, fewer procedures were found to have excessively high dose values. The proposed EC reference levels would therefore be useful for continual monitoring of CT dose status, but do not appear to provide as comprehensive an assessment of patient exposure as that given by consideration of effective doses.

Entities:  

Mesh:

Year:  2000        PMID: 10721319     DOI: 10.1259/bjr.73.865.10721319

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose-length product and the effective dose and to verify fulfilment of the diagnostic reference levels.

Authors:  Daniela Origgi; Sabrina Vigorito; Gaetano Villa; Massimo Bellomi; Giampiero Tosi
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

2.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel Long; Ryan Fisher; Chris Tien; Steven L Simon; Andre Bouville; Wesley E Bolch
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

3.  An inter-hospital comparison of patient dose based on clinical indications.

Authors:  W Teeuwisse; J Geleijns; W Veldkamp
Journal:  Eur Radiol       Date:  2006-10-24       Impact factor: 5.315

4.  Dose management in CT facility.

Authors:  V Tsapaki; M Rehani
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

5.  Cohort study of Western Australia computed tomography utilisation patterns and their policy implications.

Authors:  David A J Gibson; Rachael E Moorin; C D'Arcy J Holman
Journal:  BMC Health Serv Res       Date:  2014-11-05       Impact factor: 2.655

6.  A survey of organ equivalent and effective doses from diagnostic radiology procedures.

Authors:  Ernest K Osei; Johnson Darko
Journal:  ISRN Radiol       Date:  2012-09-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.