Abstract

The posterior regions of the mouth sustain greater forces, yet often present poorer bone density. A biomechanical approach, often presented to decrease risk factors in such regions, is to increase implant surface area. Most manufacturers provide implants in various lengths. The longest implants are typically inserted into the anterior regions of the mouth, where forces of less magnitude and superior bone quality are present. A finite element analysis supports the hypothesis that implant length is a secondary parameter for stress distribution. A common approach is to enhance implant surface area in the posterior regions primarily by focusing on diameter. However, this increases surface area by only 30% for conventional thread designs despite the fact that forces increase by > 300% in the posterior regions. A change in implant diameter and thread design may increase surface area by > 300%. Such increases in surface area may decrease stresses to the crestal bone regions and reduce both crestal bone loss and early loading implant failure.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10709483     DOI: 10.1097/00008505-199904000-00008

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  11 in total

1.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

2.  Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs.

Authors:  Dong-Seok Kim; Dae-Gon Kim; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

3.  Osseointegration of orthodontic micro-screws after immediate and early loading.

Authors:  Linkun Zhang; Zhihe Zhao; Yu Li; Jiapei Wu; Leilei Zheng; Tian Tang
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

4.  Simplifying the Treatment of Bone Atrophy in the Posterior Regions: Combination of Zygomatic and Wide-Short Implants-A Case Report with 2 Years of Follow-Up.

Authors:  Fernanda Faot; Geninho Thomé; Amália Machado Bielemann; Caio Hermann; Ana Cláudia Moreira Melo; Luis Eduardo Marques Padovan; Ivete Aparecida de Mattias Sartori
Journal:  Case Rep Dent       Date:  2016-10-27

5.  Investigation of peri-implant tissue conditions and peri-implant tissue stability in implants placed with simultaneous augmentation procedure: a 3-year retrospective follow-up analysis of a newly developed bone level implant system.

Authors:  Jonas Lorenz; Henriette Lerner; Robert A Sader; Shahram Ghanaati
Journal:  Int J Implant Dent       Date:  2017-09-05

6.  Effect of Surgical Installation of Dental Implants on Surface Topography and Its Influence on Osteoblast Proliferation.

Authors:  Helder H M Menezes; Marina M Naves; Henara L Costa; Tarsis P Barbosa; Jéssica A Ferreira; Denildo Magalhães; Elizabeth F Martinez
Journal:  Int J Dent       Date:  2018-10-17

7.  Analysis of stress distribution in ceramic and titanium implants in alveolar sockets of the anterior region of the maxilla.

Authors:  Cacilda-Cunha Ferraz; Rosália-Moreira Barros; Fábio-Cunha Ferraz; Átila-Augusto Mundstock; Bruno-Sotto Maior
Journal:  J Clin Exp Dent       Date:  2019-10-01

8.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

9.  Assessment of the relationship between the maxillary sinus and the canine root tip using cone beam computed tomography.

Authors:  Leila Khojastepour; Najmeh Movahhedian; Mohadeseh Zolghadrpour; Mohammad Mahjoori-Ghasrodashti
Journal:  BMC Oral Health       Date:  2021-07-10       Impact factor: 2.757

10.  Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study.

Authors:  Lamiaa Said Elfadaly; Lamiaa Sayed Khairallah; Mona Atteya Al Agroudy
Journal:  Int J Implant Dent       Date:  2017-07-13
View more