Literature DB >> 10708084

Hip arthroplasty with a collared straight cobalt-chrome femoral stem using second-generation cementing technique: a 10-year-average follow-up study.

A A Kale1, C J Della Valle, V H Frankel, S A Stuchin, J D Zuckerman, P E Di Cesare.   

Abstract

Clinical and radiographic results of 116 patients who had undergone 132 hip arthroplasties at our institution from 1983 to 1988 with a collared cemented straight cobalt-chrome femoral stem using second-generation cementing technique were reviewed. Twenty hips in 20 patients who were part of the original cohort were lost to follow-up. Mean age at the time of surgery was 68.2 years. Mean radiographic follow-up was 9.6 years with a minimum follow-up of 5 years. Ten-year survivorship of the component was 96.5% with revision considered as an endpoint and 94.2% with either revision or radiographic loosening considered the endpoint. Three implants (2.3%) were revised for aseptic loosening at a mean of 8.1 years after implantation. One implant (0.8%) was revised for septic loosening at 10.5 years after surgery. Of the implants not revised, 1 showed evidence of circumferential bone-cement radiolucencies, and 1 had radiolucencies at the implant-cement interface. Five of the surviving femoral components (5.0%) showed focal areas of cystic osteolysis, and proximal femoral bone resorption under the collar was seen in 32 patients (31.7%). There were no cases of cement fracture or stem subsidence. The biomechanical and material properties of this stem combined with second-generation cementing technique look promising for long-term survivorship.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10708084     DOI: 10.1016/s0883-5403(00)90198-0

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  High failure rate of a modern, proximally roughened, cemented stem for total hip arthroplasty.

Authors:  A Grose; A González Della Valle; P Bullough; S Lyman; I Tomek; P Pellicci
Journal:  Int Orthop       Date:  2006-04-29       Impact factor: 3.075

Review 2.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

3.  Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?

Authors:  Nicolas Bonin; Jean-Emmanuel Gedouin; Vincent Pibarot; Jacques Bejui-Hughues; Hugo Bothorel; Mo Saffarini; Cécile Batailler
Journal:  J Exp Orthop       Date:  2017-10-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.