Literature DB >> 10706612

Isotope-labeled immunoassays without radiation waste.

G Shan1, W Huang, S J Gee, B A Buchholz, J S Vogel, B D Hammock.   

Abstract

The practice of immunoassay has experienced a widespread transition from radioisotopic labeling to nonisotopic labeling over the last two decades. Radioisotope labels have drawbacks that hamper their applications: (i) perceived radiation hazards of reagents, (ii) regulatory requirements and disposal problems of working with radioactive materials, and (iii) short shelf-life of the labeled reagents. The advantage of isotopic labeling is the incorporation into analytes without altering structure or reactivity, as is often the case with ELISA or fluorescent detection systems. We developed a format for isotope label immunoassay with the long-life isotope (14)C as the label and accelerator mass spectrometer (AMS) as the detection system. AMS quantifies attomole levels of several isotopes, including (14)C. With this exquisite sensitivity, the sensitivity of an immunoassay is limited by the K(d) of the antibody and not the detection system. The detection limit of the assays for atrazine and 2,3,7,8-tetrachlorodibenzo-p-dioxin was 2.0 x 10(-10) M and 2.0 x 10(-11) M, respectively, approximately an order of magnitude below the standard enzyme immunoassay. Notably, <1 dpm (0.45 pCi) of (14)C-labeled compound was used in each assay, which is well below the limit of disposal (50 nCi per g) as nonradioactive waste. Thus, endogenous reporter ligands quantified by AMS provide the advantages of an RIA without the associated problems of radioactive waste.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10706612      PMCID: PMC15948          DOI: 10.1073/pnas.040575997

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  17 in total

1.  Assay of plasma insulin in human subjects by immunological methods.

Authors:  R S YALOW; S A BERSON
Journal:  Nature       Date:  1959-11-21       Impact factor: 49.962

Review 2.  Accelerator mass spectrometry.

Authors:  J S Vogel; K W Turteltaub; R Finkel; D E Nelson
Journal:  Anal Chem       Date:  1995-06-01       Impact factor: 6.986

Review 3.  Development validation and problems with the toxic equivalency factor approach for risk assessment of dioxins and related compounds.

Authors:  S H Safe
Journal:  J Anim Sci       Date:  1998-01       Impact factor: 3.159

4.  Enzyme-linked immunosorbent assay (ELISA). Quantitative assay of immunoglobulin G.

Authors:  E Engvall; P Perlmann
Journal:  Immunochemistry       Date:  1971-09

5.  Theoretical limitations on immunoassay sensitivity. Current practice and potential advantages of fluorescent Eu3+ chelates as non-radioisotopic tracers.

Authors:  T M Jackson; R P Ekins
Journal:  J Immunol Methods       Date:  1986-02-27       Impact factor: 2.303

6.  Tissue distribution and macromolecular binding of extremely low doses of [14C]-benzene in B6C3F1 mice.

Authors:  M R Creek; C Mani; J S Vogel; K W Turteltaub
Journal:  Carcinogenesis       Date:  1997-12       Impact factor: 4.944

7.  Development of a highly sensitive enzyme-linked immunosorbent assay based on polyclonal antibodies for the detection of polychlorinated dibenzo-p-dioxins.

Authors:  Y Sugawara; S J Gee; J R Sanborn; S D Gilman; B D Hammock
Journal:  Anal Chem       Date:  1998-03-15       Impact factor: 6.986

8.  Metal binding properties of a monoclonal antibody directed toward metal-chelate complexes.

Authors:  D A Blake; P Chakrabarti; M Khosraviani; F M Hatcher; C M Westhoff; P Goebel; D E Wylie; R C Blake
Journal:  J Biol Chem       Date:  1996-11-01       Impact factor: 5.157

9.  Dioxins and furans: epidemiologic assessment of cancer risks and other human health effects.

Authors:  H Becher; D Flesch-Janys
Journal:  Environ Health Perspect       Date:  1998-04       Impact factor: 9.031

10.  Accelerator mass spectrometry in biomedical dosimetry: relationship between low-level exposure and covalent binding of heterocyclic amine carcinogens to DNA.

Authors:  K W Turteltaub; J S Felton; B L Gledhill; J S Vogel; J R Southon; M W Caffee; R C Finkel; D E Nelson; I D Proctor; J C Davis
Journal:  Proc Natl Acad Sci U S A       Date:  1990-07       Impact factor: 11.205

View more
  12 in total

1.  Attomole level protein sequencing by Edman degradation coupled with accelerator mass spectrometry.

Authors:  M Miyashita; J M Presley; B A Buchholz; K S Lam; Y M Lee; J S Vogel; B D Hammock
Journal:  Proc Natl Acad Sci U S A       Date:  2001-04-03       Impact factor: 11.205

Review 2.  Accelerator mass spectrometry-enabled studies: current status and future prospects.

Authors:  Ali Arjomand
Journal:  Bioanalysis       Date:  2010-03       Impact factor: 2.681

3.  A novel immunoassay for the quantization of CYFRA 21-1 in human serum.

Authors:  An He; Tian-Cai Liu; Zhi-Ning Dong; Zhi-Qi Ren; Jing-Yuan Hou; Ming Li; Ying-Song Wu
Journal:  J Clin Lab Anal       Date:  2013-07       Impact factor: 2.352

Review 4.  Investigating metabolite-protein interactions: an overview of available techniques.

Authors:  Grace Xiaolu Yang; Xiyan Li; Michael Snyder
Journal:  Methods       Date:  2012-06-28       Impact factor: 3.608

5.  Development of a high-throughput method for real-time assessment of cellular metabolism in intact long skeletal muscle fibre bundles.

Authors:  Rui Li; Frederik J Steyn; Michael B Stout; Kevin Lee; Tanya R Cully; Juan C Calderón; Shyuan T Ngo
Journal:  J Physiol       Date:  2016-11-03       Impact factor: 5.182

6.  GABAA receptor target of tetramethylenedisulfotetramine.

Authors:  Chunqing Zhao; Sung Hee Hwang; Bruce A Buchholz; Timothy S Carpenter; Felice C Lightstone; Felice Lightstone; Jun Yang; Bruce D Hammock; John E Casida
Journal:  Proc Natl Acad Sci U S A       Date:  2014-05-27       Impact factor: 11.205

7.  Insecticide Transfer Efficiency and Lethal Load in Argentine Ants.

Authors:  L M Hooper-Bui; E S C Kwok; B A Buchholz; M K Rust; D A Eastmond; J S Vogel
Journal:  Nucl Instrum Methods Phys Res B       Date:  2015-10-15       Impact factor: 1.377

8.  Cancer Diagnostics via Ultrasensitive Multiplexed Detection of Parathyroid Hormone-Related Peptides with a Microfluidic Immunoarray.

Authors:  Brunah A Otieno; Colleen E Krause; Abby L Jones; Richard B Kremer; James F Rusling
Journal:  Anal Chem       Date:  2016-09-08       Impact factor: 6.986

Review 9.  Recent advances in biomedical applications of accelerator mass spectrometry.

Authors:  Sang Soo Hah; Paul T Henderson; Kenneth W Turteltaub
Journal:  J Biomed Sci       Date:  2009-06-17       Impact factor: 8.410

10.  Tracking Tumor Colonization in Xenograft Mouse Models Using Accelerator Mass Spectrometry.

Authors:  Nicholas R Hum; Kelly A Martin; Michael A Malfatti; Kurt Haack; Bruce A Buchholz; Gabriela G Loots
Journal:  Sci Rep       Date:  2018-10-09       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.