Literature DB >> 10703844

Indoor/outdoor PM10 and PM2.5 in Bangkok, Thailand.

F C Tsai1, K R Smith, N Vichit-Vadakan, B D Ostro, L G Chestnut, N Kungskulniti.   

Abstract

Twenty-four-hour averaged PM10 and PM2.5 concentrations were obtained by using 4-liter-per-minute-pumps and impactors in microenvironments of a busy shopping district and a university hospital campus. In both areas, most people live directly adjacent to their worksites--minimizing the need to measure commuting exposure as part of total daily exposure. Co-located samplers were set in indoor microenvironments, the near-ambient zone of the households, and at nearby streetside central ambient monitoring stations. Smoking and use of other indoor PM sources were recorded daily via questionnaires. Consistent with previous studies, smoking and the use of charcoal stoves increased indoor particulate matter levels. The sampled air-conditioned hospital area had substantially lower particle concentrations than outdoors. A simple total exposure model was used to estimate the human exposure. The averaged ratios of co-located PM2.5/PM10 concentrations in various microenvironments are reported for each location. A single daily indoor average PM10 concentration for all households measured in a given sampling day is calculated for correlation analysis. Results showed that day-to-day fluctuations of these calculated indoor PM10 levels correlated well with near-ambient data and moderately well with ambient data collected at the nearby central monitoring site. This implies that ambient monitors are able to capture the daily variations of indoor PM levels or even personal exposure and may help explain the robust association of ambient PM levels and health effects found in many epidemiological studies. Absolute PM exposures, however, were substantially underestimated by ambient monitors in the shopping district, probably because of strong local sources.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10703844     DOI: 10.1038/sj.jea.7500071

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  6 in total

Review 1.  Air particulate matter and cardiovascular disease: the epidemiological, biomedical and clinical evidence.

Authors:  Yixing Du; Xiaohan Xu; Ming Chu; Yan Guo; Junhong Wang
Journal:  J Thorac Dis       Date:  2016-01       Impact factor: 2.895

2.  Indoor exposure to respirable particulate matter and particulate-phase PAHs in rural homes in North India.

Authors:  Furquan Ahmad Ansari; Altaf Husain Khan; Devendra Kumar Patel; Huma Siddiqui; Shachi Sharma; Mohammad Ashquin; Iqbal Ahmad
Journal:  Environ Monit Assess       Date:  2009-11-26       Impact factor: 2.513

3.  Effects of Bedroom Environmental Conditions on the Severity of Obstructive Sleep Apnea.

Authors:  Sattamat Lappharat; Nutta Taneepanichskul; Sirimon Reutrakul; Naricha Chirakalwasan
Journal:  J Clin Sleep Med       Date:  2018-04-15       Impact factor: 4.062

4.  Indoor air pollution levels in public buildings in Thailand and exposure assessment.

Authors:  Aungsiri Klinmalee; Kasama Srimongkol; Nguyen Thi Kim Oanh
Journal:  Environ Monit Assess       Date:  2008-08-19       Impact factor: 2.513

5.  The Public Health and Air Pollution in Asia (PAPA) Project: estimating the mortality effects of particulate matter in Bangkok, Thailand.

Authors:  Nuntavarn Vichit-Vadakan; Nitaya Vajanapoom; Bart Ostro
Journal:  Environ Health Perspect       Date:  2008-09       Impact factor: 9.031

6.  Public Health and Air Pollution in Asia (PAPA): a multicity study of short-term effects of air pollution on mortality.

Authors:  Chit-Ming Wong; Nuntavarn Vichit-Vadakan; Haidong Kan; Zhengmin Qian
Journal:  Environ Health Perspect       Date:  2008-09       Impact factor: 9.031

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.