Verification of dynamic multileaf collimation using an electronic portal imaging device.

H V James1, S Atherton, G J Budgell, M C Kirby, P C Williams.   

Abstract

High standards of treatment verification are necessary where complex new delivery techniques, such as intensity modulated radiation therapy using dynamic multileaf collimation, are being developed. This paper describes the use of a fluoroscopic electronic portal imaging device (EPID) to provide real-time qualitative verification of leaf position during delivery of a dynamic MLC prescription in addition to off-line quantitative verification. A custom-built circuit triggers the EPID to capture a series of snap-shot images at equally spaced dose points during a dynamic MLC prescription. Real-time verification is achieved by overlaying a template of expected leaf positions onto the images as they are acquired. Quantitative off-line verification is achieved using a maximum gradient edge detection algorithm to measure individual leaf positions for comparison with required leaf positions. Investigations have been undertaken to optimize image acquisition and assess the edge detection algorithm for variations in machine dose rate, leaf velocity and beam attenuation. On-line verification enables the operator to monitor the progress of a dynamic delivery and has been used for independent confirmation of accurate dynamic delivery during intensity modulated treatments. Off-line verification allows measurement of leaf position with a precision of 1 mm although image acquisition times must be less than or equal to 140 ms to ensure coincidence of the maximum gradient in the image with the 50% dose level.

Mesh:

Year:  2000        PMID: 10701517     DOI: 10.1088/0031-9155/45/2/316

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Verification of MLC based real-time tumor tracking using an electronic portal imaging device.

Authors:  Sarah Han-Oh; Byong Yong Yi; Fritz Lerma; Barry L Berman; Minzhi Gui; Cedric Yu
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy.

Authors:  Louis Lee; Weihua Mao; Lei Xing
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

3.  A quality assurance phantom for electronic portal imaging devices.

Authors:  Indra J Das; Minsong Cao; Chee-Wai Cheng; Vladimir Misic; Klaus Scheuring; Edmund Schüle; Peter A S Johnstone
Journal:  J Appl Clin Med Phys       Date:  2011-02-02       Impact factor: 2.102

4.  The impact of continuously-variable dose rate VMAT on beam stability, MLC positioning, and overall plan dosimetry.

Authors:  Christopher Boylan; Alan McWilliam; Emily Johnstone; Carl Rowbottom
Journal:  J Appl Clin Med Phys       Date:  2012-11-06       Impact factor: 2.102

5.  Verification of dynamic and segmental IMRT delivery by dynamic log file analysis.

Authors:  Dale W Litzenberg; Jean M Moran; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Consistency and reproducibility of the VMAT plan delivery using three independent validation methods.

Authors:  Varatharaj Chandraraj; Sotirios Stathakis; Ravikumar Manickam; Carlos Esquivel; Sanjay S Supe; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2010-11-16       Impact factor: 2.102

7.  Using the frame averaging of aS500 EPID for IMRT verification.

Authors:  J Chang; C C Ling
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

8.  An EPID-based system for gantry-resolved MLC quality assurance for VMAT.

Authors:  Benjamin J Zwan; Michael P Barnes; Todsaporn Fuangord; Cameron J Stanton; Daryl J O'Connor; Paul J Keall; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.