Literature DB >> 10701513

Hardware-sensitive optimization for intensity modulated radiotherapy.

P S Cho1, R J Marks.   

Abstract

The multileaf collimator (MLC) hardware constraints are usually neglected in the process of intensity-modulated beam optimization. Consequently, it is not always possible to deliver planned beam modulation using dynamic MLC. Beam optimization is significantly diminished if the results must be approximated due to limitations imposed by the delivery device. To overcome this problem, an inverse beam optimization method which incorporates the hardware constraints has been developed. The hardware constraints, including the leaf velocity, the dose rate and the minimum required gap between opposing and adjacent leaves, were considered. An iterative search for feasible modulation was conducted alternately in the dosimetric space and the MLC position-time space. The optimization algorithm was designed for a unidirectional leaf trajectory and a constant dose rate. A scheme to reduce tongue-and-groove underdosage during optimization was also implemented. Comparisons were made between the solutions produced by this method and conventional optimization disregarding the hardware restrictions. The beam profiles generated by the conventional method were modified to satisfy the hardware specifications. The results indicate that inclusion of MLC constraints during optimization can improve the degree of conformity that is deliverable.

Mesh:

Year:  2000        PMID: 10701513     DOI: 10.1088/0031-9155/45/2/312

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  On Linear Infeasibility Arising in Intensity-Modulated Radiation Therapy Inverse Planning.

Authors:  Yair Censor; Adi Ben-Israel; Ying Xiao; James M Galvin
Journal:  Linear Algebra Appl       Date:  2008-03-01       Impact factor: 1.401

Review 2.  From analytic inversion to contemporary IMRT optimization: radiation therapy planning revisited from a mathematical perspective.

Authors:  Yair Censor; Jan Unkelbach
Journal:  Phys Med       Date:  2011-05-25       Impact factor: 2.685

3.  Clinical effect of multileaf collimator width on the incidence of late rectal bleeding after high-dose intensity-modulated radiotherapy for localized prostate carcinoma.

Authors:  Haruo Inokuchi; Takashi Mizowaki; Yoshiki Norihisa; Kenji Takayama; Itaru Ikeda; Kiyonao Nakamura; Mitsuhiro Nakamura; Masahiro Hiraoka
Journal:  Int J Clin Oncol       Date:  2015-07-12       Impact factor: 3.402

4.  Pre-segmented 2-Step IMRT with subsequent direct machine parameter optimisation - a planning study.

Authors:  Klaus Bratengeier; Jürgen Meyer; Michael Flentje
Journal:  Radiat Oncol       Date:  2008-11-06       Impact factor: 3.481

5.  Two-step intensity modulated arc therapy (2-step IMAT) with segment weight and width optimization.

Authors:  Jidi Sun; Theam Yong Chew; Juergen Meyer
Journal:  Radiat Oncol       Date:  2011-06-02       Impact factor: 3.481

6.  Correlation between urinary dose and delayed radiation cystitis after 78 Gy intensity-modulated radiotherapy for high-risk prostate cancer: A 10-year follow-up study of genitourinary toxicity in clinical practice.

Authors:  Haruo Inokuchi; Takashi Mizowaki; Yoshiki Norihisa; Kenji Takayama; Itaru Ikeda; Kiyonao Nakamura; Masahiro Hiraoka
Journal:  Clin Transl Radiat Oncol       Date:  2017-10-10
  6 in total