Literature DB >> 10699566

Mechanical characterization in shear of human femoral cancellous bone: torsion and shear tests.

K Bruyère Garnier1, R Dumas, C Rumelhart, M E Arlot.   

Abstract

In order to investigate and compare the mechanical behaviour of human cancellous bone during different shear loading modes, two tests were performed to characterise human femoral cancellous bone in shear: a torsion test until failure and a shear test using a sharpened stainless steel tube. Paired cylindrical samples were core drilled from 12 human femoral heads, symmetrically with respect to the coronal plane and along the primary trabecular direction. The distal part of the sample was assigned to a torsion test and the shear test was performed on the proximal part along two perpendicular anatomical directions. Apparent densities and tissue densities were measured on both torsion and shear specimens. The mean torsion properties were shear modulus G, 289 (183) MPa, ultimate stress tau(torsion), 6.1 (2.7) MPa, ultimate strain gamma(ultimate), 4.6 (1.3)%, yield stress tau(yield), 4.3 (1.9) MPa and yield strain gamma(yield), 1.8 (0.3)%. Strong correlation was obtained between G and tau(torsion) (r'=0.853, p<0.001). These torsion properties were correlated with apparent density of torsion specimens showing, respectively: r'=0.713, p=0.005 and r'=0.671, p=0. 008. Properties from the shear test were invariable with regard to the two tested directions then isotropic ultimate shear stress and isotropic elementary shear stress, which represent the mean values of the two tested directions were, respectively, tau(shear), 10.0 (4. 5) MPa and tau(elem), 18.8 (6.1) MPa. Both shear stresses were correlated with apparent density of shear specimens: tau(shear), r'=0.564, p=0.045 and tau(elem), r'=0.636, p=0.024. Apparent densities for shear specimens were superior than for torsion specimens (p=0.06) and the comparison was the opposite for tissue densities (p=0.028), showing strong density gradients of cancellous bone in the femoral head. These torsion and shear tests which permit the evaluation of cancellous bone behavior under two different types of shear loading, may be performed on different human sites and the measured shear properties may be compared to structural properties of cancellous bone.

Entities:  

Mesh:

Year:  1999        PMID: 10699566     DOI: 10.1016/s1350-4533(99)00096-x

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  9 in total

1.  High speed insertion of bone fracture fixation pins: a finite element penetration model with experimental comparisons.

Authors:  Matthew P Prygoski; Timotius Pasang; Steven R Schmid; Antony J Lozier
Journal:  J Mater Sci Mater Med       Date:  2011-11-01       Impact factor: 3.896

2.  Investigating the Effects of Surface-Initiated Polymerization of ε-Caprolactone to Bioactive Glass Particles on the Mechanical Properties of Settable Polymer/Ceramic Composites.

Authors:  Andrew J Harmata; Catherine L Ward; Katarzyna J Zienkiewicz; Joseph C Wenke; Scott A Guelcher
Journal:  J Mater Res       Date:  2014       Impact factor: 3.089

3.  The sensitivity of nonlinear computational models of trabecular bone to tissue level constitutive model.

Authors:  Andrew P Baumann; Xiutao Shi; Ryan K Roeder; Glen L Niebur
Journal:  Comput Methods Biomech Biomed Engin       Date:  2015-05-11       Impact factor: 1.763

4.  Shear strength behavior of human trabecular bone.

Authors:  Arnav Sanyal; Atul Gupta; Harun H Bayraktar; Ronald Y Kwon; Tony M Keaveny
Journal:  J Biomech       Date:  2012-08-09       Impact factor: 2.712

5.  Balancing the rates of new bone formation and polymer degradation enhances healing of weight-bearing allograft/polyurethane composites in rabbit femoral defects.

Authors:  Jerald E Dumas; Edna M Prieto; Katarzyna J Zienkiewicz; Teja Guda; Joseph C Wenke; Jesse Bible; Ginger E Holt; Scott A Guelcher
Journal:  Tissue Eng Part A       Date:  2013-10-02       Impact factor: 3.845

6.  Influence of thermodisinfection on microstructure of human femoral heads: duration of heat exposition and compressive strength.

Authors:  Christian Fölsch; Julian Dharma; Carlos Alfonso Fonseca Ulloa; Katrin Susanne Lips; Markus Rickert; Axel Pruss; Alexander Jahnke
Journal:  Cell Tissue Bank       Date:  2020-04-20       Impact factor: 1.522

7.  Effects of mass loading on the viability of assessing the state of healing of a fixated fractured long bone.

Authors:  W K Chiu; W H Ong; M Russ; T Tran; M Fitzgerald
Journal:  J Rehabil Assist Technol Eng       Date:  2019-04-24

8.  Mechanical response and in-situ deformation mechanism of cortical bone materials under combined compression and torsion loads.

Authors:  Xingdong Sun; Wandi Wu; Renbo Zhang; Hongru Qu; Jie Wang; Ke Xu; Liangfei Fang; Liangyuan Xu; Rui Jiang
Journal:  PLoS One       Date:  2022-07-27       Impact factor: 3.752

9.  Finite Element Analysis of Foot and Ankle Impact Injury: Risk Evaluation of Calcaneus and Talus Fracture.

Authors:  Duo Wai-Chi Wong; Wenxin Niu; Yan Wang; Ming Zhang
Journal:  PLoS One       Date:  2016-04-27       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.