Literature DB >> 10696599

Low-cost soft-copy display accuracy in the detection of pulmonary nodules by single-exposure dual-energy subtraction: comparison with hard-copy viewing.

S Kido1, K Kuriyama, N Hosomi, E Inoue, C Kuroda, T Horai.   

Abstract

This study endeavored to clarify the usefulness of single-exposure dual-energy subtraction computed radiography (CR) of the chest and the ability of soft-copy images to detect low-contrast simulated pulmonary nodules. Conventional and bone-subtracted CR images of 25 chest phantom image sets with a low-contrast nylon nodule and 25 without a nodule were interpreted by 12 observers (6 radiologists, 6 chest physicians) who rated each on a continuous confidence scale and marked the position of the nodule if one was present. Hard-copy images were 7 x 7-inch laser-printed CR films, and soft-copy images were displayed on a 21-inch noninterlaced color CRT monitor with an optimized dynamic range. Soft-copy images were adjusted to the same size as hard-copy images and were viewed under darkened illumination in the reading room. No significant differences were found between hard- and soft-copy images. In conclusion, the soft-copy images were found to be useful in detecting low-contrast simulated pulmonary nodules.

Mesh:

Year:  2000        PMID: 10696599      PMCID: PMC3453429          DOI: 10.1007/bf03168338

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  18 in total

1.  Single-exposure dual-energy computed radiography: improved detection and processing.

Authors:  D L Ergun; C A Mistretta; D E Brown; R T Bystrianyk; W K Sze; F Kelcz; D P Naidich
Journal:  Radiology       Date:  1990-01       Impact factor: 11.105

2.  Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images.

Authors:  B S Slasky; D Gur; W F Good; M A Costa-Greco; K M Harris; L A Cooperstein; H E Rockette
Journal:  Radiology       Date:  1990-03       Impact factor: 11.105

3.  Missed bronchogenic carcinoma: radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect.

Authors:  J H Austin; B M Romney; L S Goldsmith
Journal:  Radiology       Date:  1992-01       Impact factor: 11.105

4.  Subtle pulmonary abnormalities: detection on monitors with varying spatial resolutions and maximum luminance levels compared with detection on storage phosphor radiographic hard copies.

Authors:  D Otto; T M Bernhardt; U Rapp-Bernhardt; K Ludwig; A Kästner; U B Liehr; W Döhring
Journal:  Radiology       Date:  1998-04       Impact factor: 11.105

Review 5.  ROC methodology in radiologic imaging.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1986-09       Impact factor: 6.016

6.  Some practical issues of experimental design and data analysis in radiological ROC studies.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1989-03       Impact factor: 6.016

7.  Comparison of 2048-line digital display formats and conventional radiographs: an ROC study.

Authors:  A Hayrapetian; D R Aberle; H K Huang; R Fiske; C Morioka; D Valentino; M I Boechat
Journal:  AJR Am J Roentgenol       Date:  1989-05       Impact factor: 3.959

8.  One-shot dual-energy subtraction imaging.

Authors:  T Ishigaki; S Sakuma; Y Horikawa; M Ikeda; H Yamaguchi
Journal:  Radiology       Date:  1986-10       Impact factor: 11.105

9.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

10.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

View more
  1 in total

1.  Embossed radiography utilizing energy subtraction.

Authors:  Akihiro Osawa; Manabu Watanabe; Eiichi Sato; Hiroshi Matsukiyo; Toshiyuki Enomoto; Jiro Nagao; Purkhet Abderyim; Katsuo Aizawa; Etsuro Tanaka; Hidezo Mori; Toshiaki Kawai; Shigeru Ehara; Shigehiro Sato; Akira Ogawa; Jun Onagawa
Journal:  Radiol Phys Technol       Date:  2008-12-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.