| Literature DB >> 10691280 |
R H Størkson1, B Edwin, O Reiertsen, A E Faerden, O Sortland, A R Rosseland.
Abstract
Two cases are reported of perforation of the gut caused by biliary endoprosthesies in the three-year period 1993-1995. The first patient was an 81-year-old man who had perforation of the terminal ileum caused by a straight 10 French/7 cm stent which had been dislodged from the bile duct; he underwent laparotomy but did not recover. The second patient was an 86-year-old man who had perforation of the sigmoid colon caused by a straight 7 French/5 cm stent left in the duodenum during a stent exchange procedure; he was successfully treated laparoscopically. Two cases of gut perforation in a three-year period is a rather high rate of this rare complication of placement of biliary endoprostheses.Entities:
Mesh:
Year: 2000 PMID: 10691280 DOI: 10.1055/s-2000-87
Source DB: PubMed Journal: Endoscopy ISSN: 0013-726X Impact factor: 10.093