We have compared skin to epidural space distance (SED) and tip to tip distance (TTD), a measure of posterior epidural space depth (PESD), in 40 patients with a 27-gauge Whitacre needle after identification of the epidural space using the hanging drop (HD) or loss of resistance (LOR) to air technique. After the LOR technique, TTD was found to be 2 mm greater than that after the HD technique, whereas SED was the same. We conclude that identification of the epidural space can be performed successfully with both techniques, but with a diminished risk of dural damage after LOR compared with the HD technique.

Entities:  

Mesh:

Year:  1999        PMID: 10690148     DOI: 10.1093/bja/83.5.807

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  Conus medullaris trauma: is there a greater risk in parturients?

Authors:  Julie Verkooijen; Hilde Coppejans; Els Mertens; Vera Saldien; Marcel Vercauteren
Journal:  Rom J Anaesth Intensive Care       Date:  2017-10

2.  Magnetic resonance imaging predicted the therapeutic response of patients with spinal cerebrospinal fluid leakage undergoing targeted epidural blood patch.

Authors:  Hung-Chieh Chen; Jyh-Wen Chai; Chih-Cheng Wu; Po-Lin Chen; Chieh-Lin Teng
Journal:  Br J Radiol       Date:  2021-11-22       Impact factor: 3.039

3.  Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning.

Authors:  Chen Wang; Paul Calle; Justin C Reynolds; Sam Ton; Feng Yan; Anthony M Donaldson; Avery D Ladymon; Pamela R Roberts; Alberto J de Armendi; Kar-Ming Fung; Shashank S Shettar; Chongle Pan; Qinggong Tang
Journal:  Sci Rep       Date:  2022-05-31       Impact factor: 4.996

4.  Prediction of Target Epidural Blood Patch Treatment Efficacy in Spontaneous Intracranial Hypotension Using Follow-Up MRI.

Authors:  Yu-Wei Wang; Chieh-Lin Jerry Teng; Jyh-Wen Chai; Chih-Cheng Wu; Po-Lin Chen; Hung-Chieh Chen
Journal:  Diagnostics (Basel)       Date:  2022-05-06

5.  Epidural needle with embedded optical fibers for spectroscopic differentiation of tissue: ex vivo feasibility study.

Authors:  Adrien E Desjardins; Benno H W Hendriks; Marjolein van der Voort; Rami Nachabé; Walter Bierhoff; Guus Braun; Drazenko Babic; James P Rathmell; Staffan Holmin; Michael Söderman; Björn Holmström
Journal:  Biomed Opt Express       Date:  2011-05-06       Impact factor: 3.732

6.  Fiber Optic Distributed Sensing Network for Shape Sensing-Assisted Epidural Needle Guidance.

Authors:  Aida Amantayeva; Nargiz Adilzhanova; Aizhan Issatayeva; Wilfried Blanc; Carlo Molardi; Daniele Tosi
Journal:  Biosensors (Basel)       Date:  2021-11-11

Review 7.  Etiology and use of the "hanging drop" technique: a review.

Authors:  Ludmil Todorov; Timothy VadeBoncouer
Journal:  Pain Res Treat       Date:  2014-04-15