Literature DB >> 10687543

Effect of preflaring on Root ZX apex locators.

J L Ibarrola1, B L Chapman, J H Howard, K I Knowles, M O Ludlow.   

Abstract

The Root ZX apex locator is an example of a generation of apex locators that identify the terminus of the canal by measuring a ratio between two electrical impedances. Studies have shown this device to have a high degree of accuracy. However, the manufacturer warns that the performance of these devices is limited by the presence of calcifications and dentinal shaving obstructions. An in vitro study was designed to determine if preflaring of canals would facilitate the passage of files to the apical foramen by eliminating cervical interferences and to see what effect this would have on the performance of the Root ZX apex locator. Thirty-two canals were divided into two groups. Group 1 was not manipulated before use of the Root ZX apex locator and served as control. In group 2, the canals were preflared before the use of the Root Zx apex locator. The working length files were secured in place and measured with the linear measurement tool used by the Visilog 5 imaging program. Results of this study suggest that preflaring of canals will allow working length files to more consistently reach the apical foramen (p = 0.015), which in turn increases the efficacy of the Root ZX apex locator.

Entities:  

Mesh:

Year:  1999        PMID: 10687543     DOI: 10.1016/S0099-2399(99)80323-9

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  8 in total

1.  The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study.

Authors:  V Saritha; H Raghu; Twino H Kumar; Shrishail Totad; Laxmikant Kamatagi; Prahlad A Saraf
Journal:  J Conserv Dent       Date:  2021-07-05

2.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

3.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

4.  Comparison of third generation versus fourth generation electronic apex locators in detecting apical constriction: An in vivo study.

Authors:  D V Swapna; Akash Krishna; Anand C Patil; K Rashmi; Veena S Pai; M A Ranjini
Journal:  J Conserv Dent       Date:  2015 Jul-Aug

5.  Influence of root canal curvature on the accuracy of an electronic apex locator: An in vitro study.

Authors:  Lekha Santhosh; Pooja Raiththa; Srirekha Aswathanarayana; Srinivas Panchajanya; Jayakumar Thimmaraya Reddy; Shwetha Rajanna Susheela
Journal:  J Conserv Dent       Date:  2014-11

6.  In vitro detection of simulated apical root perforation with two electronic apex locators.

Authors:  Kiumars Nazari Moghaddam; Shahrzad Nazari; Leila Shakeri; Kiamars Honardar; Farshid Mirmotalebi
Journal:  Iran Endod J       Date:  2010-02-20

7.  Working length changes in curved canals after coronal flaring by using rotary files and hand file: An in vitro study.

Authors:  Rahul Kumar; Neha Khambete; Suvarna Patil; Upendra Hoshing; Ashish Medha; Roshan Shetty
Journal:  J Conserv Dent       Date:  2013-09

8.  The Efficacy of FlexMaster's IntroFile, PreRaCe and Gates Glidden Drills in Straight-Line Access: A CBCT Assessment.

Authors:  Narges Farhad Mollashahi; Mahdi Sohrabi; Leila Farhad Mollashahi; Mojdeh Mehdizadeh
Journal:  Iran Endod J       Date:  2014-07-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.