Abstract
BACKGROUND: The purpose of this study was to assess whether laboratories which do not use CD45 for gating lymphocytes with three- (or four-) color flow cytometry (non-CD45 laboratories) for CD3(+)4(+)% and CD3(+)8(+)% do worse on quality assessment (QA) studies than laboratories which do use CD45 (CD45 laboratories). METHODS: Data came from blood specimens donated by 62 donors (50 HIV-positive) assayed over 2 years (November, 1996-October, 1998) by 35 laboratories in the NIAID DAIDS Flow Cytometry QA Program. RESULTS: Non-CD45 laboratories were significantly more likely to be classified as having unacceptable inter-laboratory results (far from the group median) than CD45 laboratories (5.6% vs 1.5%, P = 0.005 for CD3(+)4(+)%; 10.4% vs 5.0%, P = 0.007 for CD3(+)8(+)%). The intra-laboratory range of results on blinded replicates was significantly more likely to be deemed unacceptable (range >4%) in non-CD45 laboratories than in CD45 laboratories for CD3(+)8(+)% (14. 5% vs 3.5%, P = 0.002) but not for CD3(+)4(+)% (2.6% vs 1.5%, P = 0. 62). These differences in favor of CD45 gating were observed even though the non-CD45 laboratories had been doing three-color flow cytometry in the QA program significantly longer (P = 0.05) than the CD45 laboratories, and so would be expected to have fewer problems with the assay. CONCLUSIONS: Laboratories which choose to use a single CD3/CD4/CD8 tube for immunophenotyping may be sacrificing both accuracy and reproducibility. Copyright 2000 Wiley-Liss, Inc.
BACKGROUND: The purpose of this study was to assess whether laboratories which do not use CD45 for gating lymphocytes with three- (or four-) color flow cytometry (non-CD45 laboratories) for CD3(+)4(+)% and CD3(+)8(+)% do worse on quality assessment (QA) studies than laboratories which do use CD45 (CD45 laboratories). METHODS: Data came from blood specimens donated by 62 donors (50 HIV-positive) assayed over 2 years (November, 1996-October, 1998) by 35 laboratories in the NIAID DAIDS Flow Cytometry QA Program. RESULTS: Non-CD45 laboratories were significantly more likely to be classified as having unacceptable inter-laboratory results (far from the group median) than CD45 laboratories (5.6% vs 1.5%, P = 0.005 for CD3(+)4(+)%; 10.4% vs 5.0%, P = 0.007 for CD3(+)8(+)%). The intra-laboratory range of results on blinded replicates was significantly more likely to be deemed unacceptable (range >4%) in non-CD45 laboratories than in CD45 laboratories for CD3(+)8(+)% (14. 5% vs 3.5%, P = 0.002) but not for CD3(+)4(+)% (2.6% vs 1.5%, P = 0. 62). These differences in favor of CD45 gating were observed even though the non-CD45 laboratories had been doing three-color flow cytometry in the QA program significantly longer (P = 0.05) than the CD45 laboratories, and so would be expected to have fewer problems with the assay. CONCLUSIONS: Laboratories which choose to use a single CD3/CD4/CD8 tube for immunophenotyping may be sacrificing both accuracy and reproducibility. Copyright 2000 Wiley-Liss, Inc.
Authors: George Janossy; Ilesh V Jani; Nicholas J Bradley; Arsene Bikoue; Tim Pitfield; Debbie K Glencross Journal: Clin Diagn Lab Immunol Date: 2002-09
Authors: Lance E Hultin; Frederick A Menendez; Patricia M Hultin; Beth D Jamieson; Maurice R G O'Gorman; Luann Borowski; Jose L Matud; Thomas N Denny; Joseph B Margolick Journal: Cytometry B Clin Cytom Date: 2007-07 Impact factor: 3.058
Authors: Janet S Staats; Jennifer H Enzor; Ana M Sanchez; Wes Rountree; Cliburn Chan; Maria Jaimes; Ray Chun-Fai Chan; Amitabh Gaur; Thomas N Denny; Kent J Weinhold Journal: J Immunol Methods Date: 2014-06-23 Impact factor: 2.303
Authors: Lance E Hultin; Marianne Chow; Beth D Jamieson; Maurice R G O'Gorman; Frederick A Menendez; Luann Borowski; Thomas N Denny; Joseph B Margolick Journal: Cytometry B Clin Cytom Date: 2010-05 Impact factor: 3.058
Authors: Calman A MacLennan; Michael K P Liu; Sarah A White; Joep J G van Oosterhout; Felanji Simukonda; Joseph Bwanali; Michael J Moore; Eduard E Zijlstra; Mark T Drayson; Malcolm E Molyneux Journal: BMJ Date: 2007-07-17
Authors: Richard Stebbings; Lili Wang; Janet Sutherland; Martin Kammel; Adolfas K Gaigalas; Manuela John; Bodo Roemer; Maren Kuhne; Rudolf J Schneider; Michael Braun; Andrea Engel; Dinesh K Dikshit; Fatima Abbasi; Gerald E Marti; Maria Paola Sassi; Laura Revel; Sook-Kyung Kim; Marc-Olivier Baradez; Tamara Lekishvili; Damian Marshall; Liam Whitby; Wang Jing; Volker Ost; Maxim Vonsky; Jörg Neukammer Journal: Cytometry A Date: 2015-02-05 Impact factor: 4.355