Literature DB >> 10673111

Mechanical validation of whole bone composite tibia models.

L Cristofolini1, M Viceconti.   

Abstract

Composite synthetic models of the human tibia have recently become commercially available as substitutes for cadaveric specimens. Their use is justified by the advantages they offer as a substitute for real tibias. The present investigation concentrated on an extensive experimental validation of the mechanical behaviour of the whole bone composite model, compared to human specimens for different loading conditions. The stiffness of the tibias was measured with a torsional load applied along the long axis, and with a bending load applied both in the latero-medial and in the antero-posterior direction. The bending stiffness of the composite tibias matched well with that of the cadaveric specimens. This was not true for the torsional stiffness. In fact, the composite tibias were much stiffer than the cadaveric specimens, possibly due to the structure of the reinforcement material. The inter-specimen variability for the composite tibias was much lower than that for the cadaveric specimens. Thus, it seems that the composite tibias are suitable to replace cadaveric specimens for certain types of test, whereas they might be unsuitable for others, depending on the loading regimen.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10673111     DOI: 10.1016/s0021-9290(99)00186-4

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  35 in total

1.  Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

Authors:  Nikhil R Oak; John R Lien; Alexander Brunfeldt; Jeffrey N Lawton
Journal:  Hand (N Y)       Date:  2017-03-23

2.  Feasibility and fidelity of practising surgical fixation on a virtual ulna bone.

Authors:  Justin LeBlanc; Carol Hutchison; Yaoping Hu; Tyrone Donnon
Journal:  Can J Surg       Date:  2013-08       Impact factor: 2.089

3.  A porous polymeric-hydroxyapatite scaffold used for femur fractures treatment: fabrication, analysis, and simulation.

Authors:  Saeid Esmaeili; Hossein Akbari Aghdam; Mehdi Motififard; Saeed Saber-Samandari; Amir Hussein Montazeran; Mohammad Bigonah; Erfan Sheikhbahaei; Amirsalar Khandan
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-08-16

4.  Locking buttons increase fatigue life of locking plates in a segmental bone defect model.

Authors:  Marc Tompkins; David J Paller; Douglas C Moore; Joseph J Crisco; Richard M Terek
Journal:  Clin Orthop Relat Res       Date:  2012-10-27       Impact factor: 4.176

5.  Opening wedge high tibial osteotomy: plate position and biomechanics of the medial tibial plateau.

Authors:  Pilar Martinez de Albornoz; Manuel Leyes; Francisco Forriol; Angelo Del Buono; Nicola Maffulli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-30       Impact factor: 4.342

6.  Biomechanical testing of a novel osteosynthesis plate for the ulnar coronoid process.

Authors:  Johannes Kiene; Jorn Bogun; Nina Brockhaus; Klaus Waizner; Arndt-Peter Schulz; Robert Wendlandt
Journal:  Shoulder Elbow       Date:  2014-05-06

7.  Biomechanical analysis of a synthetic femoral spiral fracture model: Do end caps improve retrograde flexible intramedullary nail fixation?

Authors:  Martin M Kaiser; Gregor Zachert; Robert Wendlandt; Marion Rapp; Rebecca Eggert; Christine Stratmann; Lucas M Wessel; Arndt P Schulz; Benjamin J Kienast
Journal:  J Orthop Surg Res       Date:  2011-09-18       Impact factor: 2.359

8.  Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.

Authors:  Rene Burchard; Denise Katerla; Marina Hammer; Anke Pahlkötter; Christian Soost; Gerhard Dietrich; Arne Ohrndorf; Wolfgang Richter; Markus Lengsfeld; Hans-Jürgen Christ; Jan Adriaan Graw; Claus-Peter Fritzen
Journal:  Int Orthop       Date:  2018-02-01       Impact factor: 3.075

9.  A Biomechanical Comparison Of Pin Configurations Used For Percutaneous Pinning Of Distal Tibia Fractures In Children.

Authors:  Justin Brantley; Aditi Majumdar; J Taylor Jobe; Antony Kallur; Christina Salas
Journal:  Iowa Orthop J       Date:  2016

10.  Calcium phosphate cement enhances primary stability of open-wedge high-tibial osteotomies.

Authors:  Thomas Lind-Hansen; Poul Torben Nielsen; Juozas Petruskevicius; Benny Endelt; Karl Brian Nielsen; Ivan Hvid; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-24       Impact factor: 4.342

View more