Literature DB >> 1067291

Stress analysis of porous rooted dental implants.

A M Weinstein, J J Klawitter, S C Anand, R Schuessler.   

Abstract

A model based on a continuously bonded interface predicts high punching stresses at the apex of the implant and low stresses in the cortical plates. A model based on a continuously bonded interface predicts high stiffness and a resultant low implant displacement-load ratio. A model based on a tissue ingrowth-bonded interface predicts uniform distribution of stresses around the implant through the cortical plates. A model based on a tissue ingrowth-bonded interface predicts an implant displacement-load ratio close to the ratio measured with actual implant specimens.

Mesh:

Substances:

Year:  1976        PMID: 1067291     DOI: 10.1177/00220345760550051001

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  12 in total

1.  Study of Biomechanics of Porous Coated Root Form Implant Using Overdenture Attachment: A 3D FEA.

Authors:  Ravindra C Savadi; Chhavi Goyal
Journal:  J Indian Prosthodont Soc       Date:  2011-02-01

2.  Influence of Implant Surface Topography and Loading Condition on Stress Distribution in Bone Around Implants: A Comparative 3D FEA.

Authors:  Ravindra C Savadi; Jatin Agarwal; Rolly Shrivastava Agarwal; V Rangarajan
Journal:  J Indian Prosthodont Soc       Date:  2011-10-19

3.  Angulated abutments and perimplants stress: F.E.M. analysis.

Authors:  P Cardelli; M Montani; M Gallio; M Biancolini; C Brutti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2009-12-10

4.  A Finite Element Stress Analysis of a Concical Triangular Connection in Implants: A New Proposal.

Authors:  Romy Angeles Maslucan; John Alexis Dominguez
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

5.  Biomechanical Comparison of Six Different Root-Analog Implants and the Conventional Morse Taper Implant by Finite Element Analysis.

Authors:  Jia-Qing Wang; Yuan Zhang; Min Pang; Yue-Qiu Wang; Jun Yuan; Hui Peng; Wen Zhang; Lu Dai; Hong-Wei Li
Journal:  Front Genet       Date:  2022-06-13       Impact factor: 4.772

6.  The influence of the bone-implant interface stiffness on stress profiles surrounding Al2O3 and carbon dental implants.

Authors:  C J Lavernia; S D Cook; A M Weinstein; J J Klawitter
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

7.  Force transfer and stress distribution in an implant-supported overdenture retained with a hader bar attachment: a finite element analysis.

Authors:  Preeti Satheesh Kumar; Kumar K S Satheesh; Jins John; Geetha Patil; Ruchi Patel
Journal:  ISRN Dent       Date:  2013-12-26

8.  A Novel Rat Model of Orthodontic Tooth Movement Using Temporary Skeletal Anchorage Devices: 3D Finite Element Analysis and In Vivo Validation.

Authors:  Neelambar Kaipatur; Yuchin Wu; Samer Adeeb; Thomas Stevenson; Paul Major; Michael Doschak
Journal:  Int J Dent       Date:  2014-09-10

9.  Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever.

Authors:  Ji-Man Park; Hyun-Joo Kim; Eun-Jin Park; Myung-Rae Kim; Sun-Jong Kim
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

10.  A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone.

Authors:  Hasan Sarfaraz; Anoopa Paulose; K Kamalakanth Shenoy; Akhter Hussain
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.