Literature DB >> 10667519

Regional pressure volume curves by electrical impedance tomography in a model of acute lung injury.

P W Kunst1, S H Böhm, G Vazquez de Anda, M B Amato, B Lachmann, P E Postmus, P M de Vries.   

Abstract

OBJECTIVE: A new noninvasive method, electrical impedance tomography (EIT), was used to make pressure-impedance (PI) curves in a lung lavage model of acute lung injury in pigs. The lower inflection point (LIP) and the upper deflection point (UDP) were determined from these curves and from the traditional pressure-volume (PV) curves to determine whether the PI curves resemble the traditional PV curves. Furthermore, regional differences in the mentioned determinants were investigated.
DESIGN: Prospective, experimental study.
SETTING: Animal research laboratory.
INTERVENTIONS: In nine anesthetized pigs, repeated lung lavage was performed until a Pao2 <80 torr was reached. Thereafter, an inspiratory PV curve was made using a constant flow of oxygen. During the intervention, EIT measurements were performed.
MEASUREMENTS AND MAIN RESULTS: In this study, the LIP(EIT) was within 2 cm H2O of the LIP(PV). Furthermore, it was possible to visualize regional PI curves by EIT. No significant difference was found between the LIP(PV) (21.3+/-3.0 cm H2O) and the LIP(EIT) of the total lung (21.5+/-3.0 cm H2O) or the anterior parts of the lung (21.5+/-2.9 cm H2O). A significantly higher LIP (29.5+/-4.9 cm H2O) was found in the posterior parts of the lung. A UDP(PV) could be found in three animals only, whereas in all animals a UDP(EIT) could be determined from the anterior part of the lung.
CONCLUSIONS: Using EIT, determination of LIP and UDP from the regional PI curves is possible. The obtained information from the regional PI curves may help in understanding alveolar recruitment. The use of this new bedside technique for clinical decision making remains to be examined.

Entities:  

Mesh:

Year:  2000        PMID: 10667519     DOI: 10.1097/00003246-200001000-00029

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  17 in total

1.  Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre.

Authors:  Peter A Dargaville; Peter C Rimensberger; Inéz Frerichs
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

Review 2.  [Electrical impedance tomography: ready for routine clinical use for mechanically ventilated patients?].

Authors:  J Hinz; G Hahn; M Quintel
Journal:  Anaesthesist       Date:  2008-01       Impact factor: 1.041

3.  Reconstructions of conductive and insulating targets using the D-bar method on an elliptical domain.

Authors:  E K Murphy; J L Mueller; J C Newell
Journal:  Physiol Meas       Date:  2007-06-26       Impact factor: 2.833

4.  Evaluation of an electrical impedance tomography-based Global Inhomogeneity Index for pulmonary ventilation distribution.

Authors:  Zhanqi Zhao; Knut Möller; Daniel Steinmann; Inéz Frerichs; Josef Guttmann
Journal:  Intensive Care Med       Date:  2009-08-04       Impact factor: 17.440

Review 5.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

6.  The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects.

Authors:  Thomas Riedel; Tanya Richards; Andreas Schibler
Journal:  Intensive Care Med       Date:  2005-09-30       Impact factor: 17.440

7.  Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver.

Authors:  Huibert R van Genderingen; Adrianus J van Vught; Jos R C Jansen
Journal:  Intensive Care Med       Date:  2002-12-14       Impact factor: 17.440

8.  PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography.

Authors:  Zhanqi Zhao; Daniel Steinmann; Inéz Frerichs; Josef Guttmann; Knut Möller
Journal:  Crit Care       Date:  2010-01-30       Impact factor: 9.097

9.  Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography.

Authors:  Torsten Meier; Henning Luepschen; Jan Karsten; Thorsten Leibecke; Martin Grossherr; Hartmut Gehring; Steffen Leonhardt
Journal:  Intensive Care Med       Date:  2007-07-25       Impact factor: 17.440

10.  Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial.

Authors:  Ido G Bikker; Carsten Preis; Mahamud Egal; Jan Bakker; Diederik Gommers
Journal:  Crit Care       Date:  2011-08-11       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.