Literature DB >> 10664444

Posterior occipitocervical fusion in rheumatoid arthritis and other instabilities.

D Grob1.   

Abstract

Occipitocervical fixation remains a surgical challenge. A Y-plate in combination with transarticular screw fixation provides a simple and economically favorable solution to this problem. By integrating the transarticular screws into the Y-plate immediate postoperative reliable stabilization is achieved. Clinical results confirm the reliability and the low rate of pseudarthrosis with this surgical technique.

Entities:  

Mesh:

Year:  2000        PMID: 10664444     DOI: 10.1007/s007760050013

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  8 in total

Review 1.  [Instability of the upper cervical spine due to rheumatism].

Authors:  C E Heyde; U Weber; R Kayser
Journal:  Orthopade       Date:  2006-03       Impact factor: 1.087

2.  A new method for measurement of occipitocervical angle by occiput-C3 angle.

Authors:  Sombat Kunakornsawat; Tinnakorn Pluemvitayaporn; Pritsanai Pruttikul; Suppachai Punpichet; Chaiwat Piyasakulkaew; Alisara Arirachakaran; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-11-10

3.  Occipitocervical inclination: new radiographic parameter of neutral occipitocervical position.

Authors:  Seong-Dae Yoon; Chang-Hwa Lee; Jiwoon Lee; Ji-Yeon Choi; Woo-Kie Min
Journal:  Eur Spine J       Date:  2017-05-29       Impact factor: 3.134

Review 4.  [Surgical aspects of the cervical spine in rheumatoid arthritis].

Authors:  D Grob
Journal:  Orthopade       Date:  2004-10       Impact factor: 1.087

5.  The radiological feature of anterior occiput-to-axis screw fixation as it guides the screw trajectory on 3D printed models: a feasibility study on 3D images and 3D printed models.

Authors:  Ai-Min Wu; Sheng Wang; Wan-Qing Weng; Zhen-Xuan Shao; Xin-Dong Yang; Jian-Shun Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

6.  Evaluation of an occipito-cervico fusion with a new implant design: a biomechanical study.

Authors:  Filippo Migliorini; Alice Baroncini; Yasser El Mansy; Valentin Quack; Andreas Prescher; Max Mischer; Johannes Greven; Markus Tingart; Jörg Eschweiler
Journal:  BMC Musculoskelet Disord       Date:  2021-03-06       Impact factor: 2.362

7.  Occipitocervical Revision Surgery Using the Bicortical Screw and Plate System for Failed Craniovertebral Junction Stabilization.

Authors:  Yan Sun; Feng Yang; Hao-Ning Ma; Long Gong; Yan-Lei Wang; Ji-Peng Song; Qing-Ying Hao; Ming-Sheng Tan
Journal:  Orthop Surg       Date:  2021-12-13       Impact factor: 2.071

8.  A novel method for measurement of the occipital-cervical distance via the occiput-C4 distance.

Authors:  Chao Tang; Sheng Yang; Ye Hui Liao; Qiang Tang; Fei Ma; Qing Wang; De Jun Zhong
Journal:  BMC Musculoskelet Disord       Date:  2020-06-15       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.