13C-octanoic acid breath test for gastric emptying measurement.

B Delbende1, F Perri, O Couturier, A Leodolter, P Mauger, B Bridgi, Y Bizais, S B des Varannes, A Andriulli, J P Galmiche.   

Abstract

OBJECTIVES: The purpose of this multicentre study was to assess the accuracy and reproducibility of the 13C-octanoic acid breath test compared to scintigraphy for measurement of gastric emptying.
METHODS: Sixty-nine healthy subjects (40 men, 29 women; mean age 30 years, range 21-61) were studied at least once by using the 13C-octanoic breath test. In 34 healthy subjects, gastric emptying was simultaneously measured by gastric scintigraphy, and the 13C-octanoic breath test was then repeated in 18 of these cases. Fifty-four patients (30 men, 24 women; mean age 46 years, range 13-74) with dyspeptic or reflux symptoms were studied according to the same procedure.
RESULTS: The correlation between breath test and scintigraphic values was highly significant (r = 0.744, P<0.001). The concordance of results of scintigraphy and breath test (normal versus abnormal) and the reproducibility (Bland and Altman method) of the breath test were good (CVinter = 24%, CVintra = 15%). As compared to scintigraphy, breath test detected an abnormal gastric emptying with 67% sensitivity and 80% specificity (ROC analysis).
CONCLUSION: These results confirm the value of breath test as an accurate measurement of gastric emptying. Its excellent reproducibility makes it a method of choice for pharmacological studies. However, at least when scintigraphy is considered the gold standard, breath test sensitivity may be insufficient for the detection of gastroparesis in an individual patient.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10656216     DOI: 10.1097/00042737-200012010-00016

Source DB:  PubMed          Journal:  Eur J Gastroenterol Hepatol        ISSN: 0954-691X            Impact factor:   2.566


  18 in total

1.  Theoretical flaws in the gastric emptying breath test: why is it dubious?

Authors:  Masaki Sanaka; Takatsugu Yamamoto; Yasushi Kuyama
Journal:  Dig Dis Sci       Date:  2005-01       Impact factor: 3.199

Review 2.  The Wireless Motility Capsule: a One-Stop Shop for the Evaluation of GI Motility Disorders.

Authors:  Richard J Saad
Journal:  Curr Gastroenterol Rep       Date:  2016-03

3.  Comparison of upper gastrointestinal contrast studies and pH/impedance tests for the diagnosis of childhood gastro-oesophageal reflux.

Authors:  Eva W Macharia
Journal:  Pediatr Radiol       Date:  2012-08-04

Review 4.  Update on diagnostic value of breath test in gastrointestinal and liver diseases.

Authors:  Imran Siddiqui; Sibtain Ahmed; Shahab Abid
Journal:  World J Gastrointest Pathophysiol       Date:  2016-08-15

5.  Short- and medium-term reproducibility of gastric emptying of a solid meal determined by a low dose of 13C-octanoic acid and nondispersive isotope-selective infrared spectrometry.

Authors:  Anna Kasicka-Jonderko; Magdalena Kamińska; Krzysztof Jonderko; Olga Setera; Barbara Błońska-Fajfrowska
Journal:  World J Gastroenterol       Date:  2006-02-28       Impact factor: 5.742

6.  Measuring gastric emptying: comparison of 13C-octanoic acid breath test and scintigraphy.

Authors:  Jari Punkkinen; Ilmari Konkka; Olli Punkkinen; Tapani Korppi-Tommola; Martti Färkkilä; Jari Koskenpato
Journal:  Dig Dis Sci       Date:  2006-02       Impact factor: 3.199

7.  Simultaneous measurement of gastric emptying with a simple muffin meal using [13C]octanoate breath test and scintigraphy in normal subjects and patients with dyspeptic symptoms.

Authors:  Matthew Q Bromer; Steve B Kantor; David A Wagner; Linda C Knight; Alan H Maurer; Henry P Parkman
Journal:  Dig Dis Sci       Date:  2002-07       Impact factor: 3.199

8.  Gastric emptying measurement of liquid nutrients using the (13)C-octanoate breath test in critically ill patients: a comparison with scintigraphy.

Authors:  Nam Q Nguyen; Laura K Bryant; Carly M Burgstad; Marianne Chapman; Adam Deane; Max Bellon; Kylie Lange; Dylan Bartholomeuz; Michael Horowitz; Richard H Holloway; Robert J Fraser
Journal:  Intensive Care Med       Date:  2013-03-08       Impact factor: 17.440

9.  Sensitivity and specificity of an abbreviated (13)C-mixed triglyceride breath test for measurement of pancreatic exocrine function.

Authors:  Jutta Keller; Viola Meier; Kristina U Wolfram; Ulrich Rosien; Peter Layer
Journal:  United European Gastroenterol J       Date:  2014-08       Impact factor: 4.623

10.  Microgravity Simulated by the 6° Head-Down Tilt Bed Rest Test Increases Intestinal Motility but Fails to Induce Gastrointestinal Symptoms of Space Motion Sickness.

Authors:  Meher Prakash; Ron Fried; Oliver Götze; Francisca May; Petra Frings-Meuthen; Edwin Mulder; Judit Valentini; Mark Fox; Michael Fried; Werner Schwizer; Benjamin Misselwitz
Journal:  Dig Dis Sci       Date:  2015-06-09       Impact factor: 3.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.