Literature DB >> 10653033

Bioprosthetic heart valve leaflet motion monitored by dual camera stereo photogrammetry.

Z B Gao1, S Pandya, N Hosein, M S Sacks, N H Hwang.   

Abstract

Dual camera stereo photogrammetry (DCSP) was applied to investigate the leaflet motion of bioprosthetic heart valves (BHVs) in a physiologic pulse flow loop (PFL). A 25-mm bovine pericardial valve was installed in the aortic valve position of the PFL, which was operated at a pulse rate of 70 beats/min and a cardiac output of 5 l/min. The systolic/diastolic aortic pressure was maintained at 120/80 mmHg to mimic the physiologic load experienced by the aortic valve. The leaflet of the test valve was marked with 80 India ink dots to form a fan-shaped matrix. From the acquired image sequences, 3-D coordinates of the marker matrix were derived and hence the surface contour, local mean and Gaussian curvatures at each opening and closing phase during one cardiac cycle were reconstructed. It is generally believed that the long-term failure rate of BHV is related to the uneven distribution of mechanical stresses occurring in the leaflet material during opening and closing. Unfortunately, a quantitative analysis of the leaflet motion under physiological conditions has not been reported. The newly developed technique permits frame-by-frame mapping of the leaflet surface, which is essential for dynamic analysis of stress-strain behavior in BHV.

Entities:  

Mesh:

Year:  2000        PMID: 10653033     DOI: 10.1016/s0021-9290(99)00165-7

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Dynamic and fluid-structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models.

Authors:  Ming-Chen Hsu; David Kamensky; Fei Xu; Josef Kiendl; Chenglong Wang; Michael C H Wu; Joshua Mineroff; Alessandro Reali; Yuri Bazilevs; Michael S Sacks
Journal:  Comput Mech       Date:  2015-06       Impact factor: 4.014

2.  Role of Computational Simulations in Heart Valve Dynamics and Design of Valvular Prostheses.

Authors:  Krishnan B Chandran
Journal:  Cardiovasc Eng Technol       Date:  2010-03       Impact factor: 2.495

Review 3.  Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance.

Authors:  Joao S Soares; Kristen R Feaver; Will Zhang; David Kamensky; Ankush Aggarwal; Michael S Sacks
Journal:  Cardiovasc Eng Technol       Date:  2016-08-09       Impact factor: 2.495

4.  FLOW DYNAMIC COMPARISON BETWEEN RECESSED HINGE AND OPEN PIVOT BI-LEAFLET HEART VALVE DESIGNS.

Authors:  V Govindarajan; H S Udaykumar; K B Chandran
Journal:  J Mech Med Biol       Date:  2009-06-01       Impact factor: 0.897

5.  Controlled cyclic stretch bioreactor for tissue-engineered heart valves.

Authors:  Zeeshan H Syedain; Robert T Tranquillo
Journal:  Biomaterials       Date:  2009-05-26       Impact factor: 12.479

6.  Automatic segmentation and tracking of biological prosthetic heart valves.

Authors:  Maryam Alizadeh; Melissa Cote; Alexandra Branzan Albu
Journal:  J Med Imaging (Bellingham)       Date:  2021-02-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.