Literature DB >> 10646144

Agreement and repeatability of pupillometry using videokeratography and infrared devices.

B S Boxer Wachler1, R R Krueger.   

Abstract

PURPOSE: To evaluate the accuracy and repeatability of the pupil-measuring modules of several corneal topography devices.
SETTING: Department of Ophthalmology, Saint Louis University Eye Institute, St. Louis, Missouri, USA.
METHODS: In 14 eyes of 7 healthy myopic patients, pupillometry was performed with 3 corneal topography devices and with an infrared pupillometer under luminance-matched conditions for the Placido projection of the topography devices. Pupils were also measured under a mesopic condition. Outcomes were pupil diameters, limits of agreement, and coefficient of repeatability of the topography devices.
RESULTS: Mean pupil diameter measurements with the Technomed C-Scan, Humphrey Masterview, Alcon EyeMap, and under a mesopic condition were 3.35 mm, 2.96 mm, 2.34 mm, and 5.94 mm, respectively. All pupil diameter measurements differed significantly from one another except those by the Masterview and C-Scan devices. The mean difference between the C-Scan and luminance-matched infrared measurements was 0.74 mm and between the Masterview and luminance-matched infrared measurements, 0.27 mm. The limits of agreement +/- 2 standard deviations was 4.12 mm and 1.56 mm for the C-Scan and Masterview devices, respectively. Coefficients of repeatability were 0.56 mm, 0.46 mm, and 0.44 mm for the C-Scan, Masterview, and EyeMap devices, respectively.
CONCLUSIONS: Although topography pupillometry was repeatable, it underestimated the largest natural pupil diameter because of the luminance of the Placido rings. The difference in limits of agreement between the C-Scan and Masterview devices may be explained by pupil physiology and the static nature of videokeratoscopy. These results have implications when topography pupillometry is used to assess pupil diameters prior to refractive surgery. We do not recommend using pupil diameters measured by topography to preoperatively determine halo-related safety.

Entities:  

Mesh:

Year:  2000        PMID: 10646144     DOI: 10.1016/s0886-3350(99)00331-4

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Scotopic pupil size in a normal pediatric population using infrared pupillometry.

Authors:  Eva-Maria Kohnen; Alina A Zubcov; Thomas Kohnen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-11-07       Impact factor: 3.117

2.  Comparison of three different technologies for pupil diameter measurement.

Authors:  Sabine Schmitz; Frank Krummenauer; Sebastian Henn; H Burkhard Dick
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-05-09       Impact factor: 3.117

3.  A simple infrared-augmented digital photography technique for detection of pupillary abnormalities.

Authors:  Tarek A Shazly; G R Bonhomme
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-01-15       Impact factor: 3.117

4.  Immediate effects of a thoracic spine thrust manipulation on the autonomic nervous system: a randomized clinical trial.

Authors:  Rob Sillevis; Joshua Cleland; Madeleine Hellman; Kristina Beekhuizen
Journal:  J Man Manip Ther       Date:  2010-12

5.  The effects of tramadol on static and dynamic pupillometry in healthy subjects--the relationship between pharmacodynamics, pharmacokinetics and CYP2D6 metaboliser status.

Authors:  Frank Fliegert; Burkhard Kurth; Karin Göhler
Journal:  Eur J Clin Pharmacol       Date:  2005-05-20       Impact factor: 2.953

6.  Intrasession repeatability of pupil size measurements under different light levels provided by a multidiagnostic device in healthy eyes.

Authors:  David P Piñero; Dolores de Fez; Inmaculada Cabezos; Alberto López-Navarro; María T Caballero; Vicente J Camps
Journal:  BMC Ophthalmol       Date:  2020-08-31       Impact factor: 2.209

7.  The immediate effect of a single session of pain neuroscience education on pain and the autonomic nervous system in subjects with persistent pain, a pilot study.

Authors:  Rob Sillevis; Gabriel Trincado; Eric Shamus
Journal:  PeerJ       Date:  2021-05-31       Impact factor: 2.984

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.