A simplified paired neck chamber for the demonstration of baroreflex blood pressure regulation.

N M Raine1, N T Cable.   

Abstract

In this investigation a simplified variable-pressure paired neck chamber was developed as a practical alternative to traditional neck collar designs used to study the arterial baroreceptor reflex in humans. The purpose of this new design was to extend the use of the noninvasive neck chamber method of baroreceptor investigation to teachers of physiology. Performance tests indicate that these new chambers are capable of delineating the stimulus-response relationship for both the blood pressure baroreflex [sensitivity = 0.425 +/- 0.13 mmHg mean arterial pressure (MAP)/mmHg neck chamber pressure (NCP); range = 24.9 +/- 4.6 mmHg MAP] and the heart rate baroreflex (sensitivity 0.273 +/- 0.12 beats.min-1.mmHg NCP-1; range = 16.7 +/- 6.8 beats/min). This was achieved by applying localized positive and negative air pressures to the carotid sinuses throughout the range from +60 to -60 mmHg in steps of 20 mmHg. This simplified neck chamber method offers distinct methodological advantages over traditional neck collars, making it a valuable tool for demonstrating baroreflex regulation of the circulation.

Entities:  

Mesh:

Year:  1999        PMID: 10644262     DOI: 10.1152/advances.1999.277.6.S60

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

Review 1.  Carotid baroreflex testing using the neck collar device.

Authors:  Victoria L Cooper; Roger Hainsworth
Journal:  Clin Auton Res       Date:  2009-02-19       Impact factor: 4.435

2.  Haemodynamic changes during neck pressure and suction in seated and supine positions.

Authors:  S Ogoh; P J Fadel; F Monteiro; W L Wasmund; P B Raven
Journal:  J Physiol       Date:  2002-04-15       Impact factor: 5.182

3.  The influence of small fibre muscle mechanoreceptors on the cardiac vagus in humans.

Authors:  V F Gladwell; J Fletcher; N Patel; L J Elvidge; D Lloyd; S Chowdhary; J H Coote
Journal:  J Physiol       Date:  2005-06-09       Impact factor: 5.182

4.  Third-degree atrioventricular block followed by syncope, labile hypertension, and orthostatic hypotension in a patient with nasopharyngeal cancer: baroreflex failure.

Authors:  Rohan V Shah; Kinjan P Patel; Christopher Manion; Ashok Runkana; Ali Hama Amin; Abnash Jain
Journal:  Am J Cardiovasc Dis       Date:  2018-06-15

5.  Noiseless Variable-Pressure Neck Chamber Device to Assess the Carotid Baroreflex Function.

Authors:  Alessandro Pinheiro; Lauro C Vianna; Jake C Carmo
Journal:  Front Physiol       Date:  2021-01-20       Impact factor: 4.566

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.