Literature DB >> 10644117

Hepatic lesion detection after superparamagnetic iron oxide enhancement: comparison of five T2-weighted sequences at 1.0 T by using alternative-free response receiver operating characteristic analysis.

J Ward1, F Chen, J A Guthrie, D Wilson, J P Lodge, J I Wyatt, P J Robinson.   

Abstract

PURPOSE: To compare the accuracy of five T2-weighted sequences in the detection of liver lesion at magnetic resonance (MR) imaging after superparamagnetic iron oxide (SPIO) enhancement.
MATERIALS AND METHODS: Forty-nine candidates for hepatic resection with known coloretal metastases were examined. Before SPIO enhancement, fast spin-echo (SE) images were obtained. After enhancement, the same fast SE sequence and long; TR/short TE, short TE, long TR/TE, and T2-weighted fast low-angle shot (FLASH) sequences were used. All images were viewed independently by four observers who were blinded to the results of the other imaging sequences, the results of the other observers, and the findings at surgery and histopathologic examination. Four weeks after the initial reading, the combined long TR/short TE and long TR/TE dual-echo images were also viewed as an additional set. The alternative free response receiver operating characteristic (ROC) method was used to analyze the results, which were correlated with findings at surgery, intraoperative ultrasonography, and histopathologic examination.
RESULTS: Irrespective of lesion size, the accuracy of all sequences after enhancement was significantly greater than that of the nonenhanced fast SE sequence (P < .01). Dual-echo and FLASH sequences were significantly more accurate than the enhanced fast SE sequence (P < .03 or P < .02, respectively). For all lesions, lesions smaller than 1 cm, and lesions 1 cm or larger, mean accuracies were as follows: dual-echo, 0.75, 0.54, and 0.93; FLASH, 0.75, 0.54, and 0.95; and enhanced fast SE, 0.72, 0.49, and 0.92.
CONCLUSION: At 1.0 T, dual-echo and FLASH sequences are the most accurate pulse sequences after SPIO enhancement.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10644117     DOI: 10.1148/radiology.214.1.r00ja21159

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Spiral CT in gastric carcinoma: comparison with barium study, fiberoptic gastroscopy and histopathology.

Authors:  Feng Chen; Yi-Cheng Ni; Kai-Er Zheng; Sheng-Hong Ju; Jun Sun; Xi-Long Ou; Man-Hua Xu; Hao Zhang; Guy Marchal
Journal:  World J Gastroenterol       Date:  2003-07       Impact factor: 5.742

2.  Nanoimmunoliposome delivery of superparamagnetic iron oxide markedly enhances targeting and uptake in human cancer cells in vitro and in vivo.

Authors:  Chengli Yang; Antonina Rait; Kathleen F Pirollo; John A Dagata; Natalia Farkas; Esther H Chang
Journal:  Nanomedicine       Date:  2008-07-26       Impact factor: 5.307

3.  Efficacy of double arterial phase dynamic magnetic resonance imaging with the sensitivity encoding technique versus dynamic multidetector-row helical computed tomography for detecting hypervascular hepatocellular carcinoma.

Authors:  Seishi Kumano; Masahiko Uemura; Toyoaki Haraikawa; Masaaki Hirata; Keiichi Kikuchi; Tonsok Kim; Masahiro Okada; Teruhito Mochizuki; Takamichi Murakami
Journal:  Jpn J Radiol       Date:  2009-07-22       Impact factor: 2.374

4.  Feng Chen's work on translational and clinical imaging.

Authors:  Feng Chen
Journal:  World J Radiol       Date:  2011-04-28

5.  A diagnostic paradigm for resectable liver lesions: to biopsy or not to biopsy?

Authors:  Adrian B Cresswell; Fenella K S Welsh; Myrddin Rees
Journal:  HPB (Oxford)       Date:  2009-11       Impact factor: 3.647

6.  Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: comparison of superparamagnetic iron oxide-enhanced MR imaging with dual-phase spiral CT.

Authors:  Jeong-Min Lee; In-Hwan Kim; Hyo-Sung Kwak; Ji-Hyun Youk; Young-Min Han; Chong-Soo Kim
Journal:  Korean J Radiol       Date:  2003 Jan-Mar       Impact factor: 3.500

Review 7.  New MR techniques for the detection of liver metastases.

Authors:  J Ward
Journal:  Cancer Imaging       Date:  2006-05-31       Impact factor: 3.909

8.  Optimal pulse sequence for ferumoxides-enhanced MR imaging used in the detection of hepatocellular carcinoma: a comparative study using seven pulse sequences.

Authors:  Seung Hoon Kim; Dongil Choi; Jae Hoon Lim; Won Jae Lee; Hyun Jung Jang; Hyo Keun Lim; Soon Jin Lee; Jae Min Cho; Seung Kwon Kim; Gab Chul Kim
Journal:  Korean J Radiol       Date:  2002 Apr-Jun       Impact factor: 3.500

9.  Small malignant hepatic tumor detection in gadolinium- and ferucarbotran-enhanced magnetic resonance imaging: does combining ferucarbotran-enhanced T2*-weighted gradient echo and T2-weighted turbo spin echo images have additive efficacy?

Authors:  Young Kon Kim; Young Hwan Lee; Hyo Sung Kwak; Chong Soo Kim; Young Min Han
Journal:  Korean J Radiol       Date:  2008 Nov-Dec       Impact factor: 3.500

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.