The pediatric disposable end-tidal carbon dioxide detector role in endotracheal intubation in newborns.

H F Aziz1, J B Martin, J J Moore.   

Abstract

OBJECTIVE: To determine the practical value of the new pediatric disposable ETCO2 detector Pedi-CAP in verifying endotracheal tube placement in neonatal resuscitation.
METHODS: Infants who required endotracheal intubation in the delivery room or the neonatal intensive care unit (NICU) were included in a prospective study in which the endotracheal tube placement was determined clinically and simultaneously by the Pedi-CAP and confirmed by chest radiograph. The Pedi-CAP and clinical evaluation determination times of the endotracheal tube placement were measured and compared. The accuracy and ease of the Pedi-CAP use were tested.
RESULTS: Forty-five newborns (450 to 4620 gm) who needed endotracheal intubation were included in the study. Twenty-four (53.3%) were intubated in the delivery room and 21 (46.7%) in the NICU. The Pedi-CAP color indicator correlated with the clinical evaluation and radiograph findings of proper intubation in 30 of 33 patients (sensitivity 91%, specificity 100%, positive predictive value 100%, and negative predictive value 80%). There were three false-negative results in patients with severe cardiorespiratory depression. The Pedi-CAP color indicator correlated with the clinical evaluation for the ET-tube being in the esophagus in 12 of 12 patients (sensitivity, specificity, and positive and negative predictive value were all 100%). The time required to determine the tube position by clinical evaluation was 0 to 90 seconds (mean = 39.7 seconds; SD +/- 15.3 seconds). The time required with the disposable ETCO2 detector was 4 to 12 seconds (mean = 8.1 seconds; SD +/- 2.9 seconds; p < 0.001).
CONCLUSION: The use of a disposable pediatric endotracheal CO2 detector significantly reduces the time spent in verifying the endotracheal tube position (trachea versus esophagus) in newborns, including premature babies with body weight < 1000 gm. This is of particular benefit to babies who are erroneously intubated in the esophagus, because using the device allows much faster detection of this problem and much earlier reintubation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10642970     DOI: 10.1038/sj.jp.7200136

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  15 in total

Review 1.  Are carbon dioxide detectors useful in neonates?

Authors:  E J Molloy; K Deakins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

2.  A summary of the changes in paediatric and neonatal resuscitation guidelines from the International Liaison Committee on Resuscitation document.

Authors:  Allan de Caen; Nalini Singhal
Journal:  Paediatr Child Health       Date:  2006-01       Impact factor: 2.253

3.  Singapore Neonatal Resuscitation Guidelines 2016.

Authors:  Cheo Lian Yeo; Agnihotri Biswas; Teong Tai Kenny Ee; Amutha Chinnadurai; Vijayendra Ranjan Baral; Alvin Shang Ming Chang; Imelda Lustestica Ereno; Kah Ying Selina Ho; Woei Bing Poon; Varsha Atul Shah; Bin Huey Quek
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

Review 4.  End tidal carbon dioxide monitoring in prehospital and retrieval medicine: a review.

Authors:  M J Donald; B Paterson
Journal:  Emerg Med J       Date:  2006-09       Impact factor: 2.740

5.  Singapore Neonatal Resuscitation Guidelines 2021.

Authors:  Agnihotri Biswas; Selina Kah Ying Ho; Wai Yan Yip; Khadijah Binti Abdul Kader; Juin Yee Kong; Kenny Teong Tai Ee; Vijayendra Ranjan Baral; Amutha Chinnadurai; Bin Huey Quek; Cheo Lian Yeo
Journal:  Singapore Med J       Date:  2021-08       Impact factor: 1.858

6.  Neonatal resuscitation: Current issues.

Authors:  Indu A Chadha
Journal:  Indian J Anaesth       Date:  2010-09

7.  Efficacy and user preference of two CO2 detectors in an infant mannequin randomized crossover trial.

Authors:  G A Hawkes; B J O'Connell; V Livingstone; C P Hawkes; C A Ryan; E M Dempsey
Journal:  Eur J Pediatr       Date:  2013-06-12       Impact factor: 3.183

8.  Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial.

Authors:  S van Os; P-Y Cheung; K Kushniruk; M O'Reilly; K Aziz; G M Schmölzer
Journal:  J Perinatol       Date:  2016-01-14       Impact factor: 2.521

Review 9.  Question 2. Should carbon dioxide detectors be used to check correct placement of endotracheal tubes in preterm and term neonates?

Authors:  Harsha Gowda
Journal:  Arch Dis Child       Date:  2011-12       Impact factor: 3.791

10.  Clinical practice: neonatal resuscitation. A Dutch consensus.

Authors:  Frank A M van den Dungen; Mariëtte B van Veenendaal; A L M Mulder
Journal:  Eur J Pediatr       Date:  2009-10-20       Impact factor: 3.183

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.