OBJECTIVES: to evaluate the intra- and interobserver variability in measurements of the aorta and iliac arteries in patients with abdominal aortic aneurysms (AAAs) considered for endovascular repair using computed tomography angiography (CTA). METHODS: the diameter of the neck, aneurysm, right and left iliac artery were measured by 5 observers in 10 consecutive patients. Measurements were performed on hard copy using a ruler and on a workstation using an electronic caliper. RESULTS: the intraobserver variability showed a decrease going from hard copy to workstation in the standard deviation of the differences of the paired observations for the neck from 3.54 mm to 1.18 mm; for the aorta from 4.16 to 1.72 mm; for the right iliac from 1.87 to 1.01 mm; for the left iliac from 2.07 to 0.87 mm. The interobserver variability showed a similar decrease for the neck in all ten pairs of observers; for the aorta in two, for the right iliac and left iliac in five. However, the difference between observers regularly exceeded 2 mm. CONCLUSION: the use of a workstation and electronic calipers results in lower intra- and interobserver variability. However, the results still show a clinically relevant difference between the observers. Therefore, it is necessary to develop an automatic observer-independent measurement technique. Copyright 1999 Harcourt Publishers Ltd.
OBJECTIVES: to evaluate the intra- and interobserver variability in measurements of the aorta and iliac arteries in patients with abdominal aortic aneurysms (AAAs) considered for endovascular repair using computed tomography angiography (CTA). METHODS: the diameter of the neck, aneurysm, right and left iliac artery were measured by 5 observers in 10 consecutive patients. Measurements were performed on hard copy using a ruler and on a workstation using an electronic caliper. RESULTS: the intraobserver variability showed a decrease going from hard copy to workstation in the standard deviation of the differences of the paired observations for the neck from 3.54 mm to 1.18 mm; for the aorta from 4.16 to 1.72 mm; for the right iliac from 1.87 to 1.01 mm; for the left iliac from 2.07 to 0.87 mm. The interobserver variability showed a similar decrease for the neck in all ten pairs of observers; for the aorta in two, for the right iliac and left iliac in five. However, the difference between observers regularly exceeded 2 mm. CONCLUSION: the use of a workstation and electronic calipers results in lower intra- and interobserver variability. However, the results still show a clinically relevant difference between the observers. Therefore, it is necessary to develop an automatic observer-independent measurement technique. Copyright 1999 Harcourt Publishers Ltd.