Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets: 5-year results.

D M Davis1, M E Packer.   

Abstract

PURPOSE: The purpose of this work was to report on the use of implant-stabilized overdentures in the mandible using the Astra Tech implant system with either ball attachments or magnets as the retentive mechanism.
MATERIALS AND METHODS: Mandibular overdentures that used ball attachments on 2 implants were provided for 13 edentulous patients; 12 edentulous patients were provided with mandibular overdentures with magnet retention, using 2 implants in 10 patients and 3 implants in 2 patients. Once they were comfortable, the participants were placed on annual recall. Any other visits were initiated by the patients. Detailed records were kept for all visits. At the annual recall the following parameters were monitored: plaque levels, mucosal health, marginal bone levels, and the patients' assessment of the treatment. The patients were followed for 5 years.
RESULTS: There was no statistical difference between the 2 groups for mucosal health and postinsertion maintenance. The magnet group had more abutment surfaces covered with plaque. Statistical analysis of the patients' subjective assessment of their treatment showed that the magnet group was less comfortable and chewing was less effective.
CONCLUSION: The results indicate that both ball attachments and magnets used on isolated Astra Tech implants in the mandible are viable treatment options. Both attachment mechanisms provided patient satisfaction, although the ball attachments were better in this respect than the magnets.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10635189

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  6 in total

1.  Attachment systems for mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Jeong-Yol Lee; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

2.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

3.  A comparative evaluation of immediate versus delayed loading of two implants with mandibular overdenture: An in vivo study.

Authors:  Param Dev Singh; Varun Kumar; Geeta Arya
Journal:  Natl J Maxillofac Surg       Date:  2019 Jan-Jun

4.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

5.  Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns - a finite element analysis.

Authors:  Meer Rownaq Ali Abbasi; Dileep Nag Vinnakota; Vijaya Sankar; Rekhalakshmi Kamatham
Journal:  Med Pharm Rep       Date:  2020-04-22

6.  Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study.

Authors:  Selda Arat Bilhan; Onur Geckili; Altug Cilingir; Ergun Bozdag; Hakan Bilhan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-08-28
  6 in total