Literature DB >> 10635177

A human histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces.

R J Lazzara1, T Testori, P Trisi, S S Porter, R L Weinstein.   

Abstract

A human histologic study was conducted to compare the percentage of bone-to-implant contact (BIC) at 6 months for Osseotite and machined, commercially pure titanium implant surfaces. To eliminate potential influences caused by differences in bone density at different intraoral locations, 2 mm x 5 mm, threaded, 2-surfaced titanium implants were manufactured; 1 side received the Osseotite surface modification and the opposite side maintained a machined surface. In each of 11 patients, 1 test implant was placed in the posterior maxilla (Types III and IV bone) during conventional dental implant surgery. Following 6 months of unloaded healing, the conventional implants were uncovered, and the test implants and surrounding hard tissue were removed. Histologic analysis indicated that at 6 months of unloaded healing, the mean BIC value for the Osseotite surfaces (72.96% +/- 25.13%) was statistically significantly higher (P < 0.05) than the mean BIC value for the machined surfaces (33.98% +/- 31.04%). When the BIC values for the machined and Osseotite surface pairs were ranked from high to low based on the machined BIC value range of 93% to 0%, the upper 50th percentile (20 surface pairs) mean BIC value was 86.1% +/- 16.7% for the Osseotite surfaces and 60.1% +/- 18.3% for the machined surfaces. The lower 50th percentile (19 surface pairs) mean BIC value was 59.1% +/- 25.3% for the Osseotite surfaces and 6.5% +/- 10.8% for the machined surfaces. Differences between mean BIC values for the 2 surfaces in both the upper and lower 50th percentiles were statistically significant (P < 0.05). The results of this study indicate that in the poorer quality bone typically found in the posterior maxilla, a statistically significantly higher percentage of bone contacts Osseotite surfaces when compared to opposing machined surfaces on the same implant.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10635177

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  16 in total

1.  Macroscopic and microscopic evaluation of a new implant design supporting immediately loaded full arch rehabilitation.

Authors:  Stefano Tetè; Vincenzo Zizzari; Alessandro De Carlo; Bruna Sinjari; Enrico Gherlone
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

2.  Comparing the TiOblast and Osseospeed surfaces. Histomorphometric and histological analysis in humans.

Authors:  M Rocci; A Rocci; M Martignoni; T Albrektsson; A Barlattani; M Gargari
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

Review 3.  Comparing success of immediate versus delay loading of implants in fresh sockets: a systematic review and meta-analysis.

Authors:  Ebrahim Eini; Hojatollah Yousefimanesh; Alireza Hashemi Ashtiani; Amal Saki-Malehi; Amin Olapour; Fakher Rahim
Journal:  Oral Maxillofac Surg       Date:  2021-07-12

4.  Assessment of the Tissue Response to Modification of the Surface of Dental Implants with Carboxyethylphosphonic Acid and Basic Fibroblastic Growth Factor Immobilization (Fgf-2): An Experimental Study on Minipigs.

Authors:  Javier Aragoneses; Ana Suárez; Nansi López-Valverde; Francisco Martínez-Martínez; Juan Manuel Aragoneses
Journal:  Biology (Basel)       Date:  2021-04-23

5.  The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants.

Authors:  Ji-Hyun Kim; Yeek Herr; Jong-Hyuk Chung; Seung-Il Shin; Young-Hyuk Kwon
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

6.  Survival of 352 titanium implants placed in 181 patients: a 4-year multicenter field study.

Authors:  Seung-Il Shin; Jeong-Ho Yun; Sung-Geun Kim; Byoungkyou Park; Yeek Herr; Jong-Hyuk Chung
Journal:  J Periodontal Implant Sci       Date:  2014-02-26       Impact factor: 2.614

7.  Immediate provisionalization and nonfunctional loading of a single implant in the maxillary esthetic zone: a clinical presentation and parameters for consideration.

Authors:  Konstantinos X Michalakis; Christos D R Kalpidis; Yvone Kirmanidou; Hiroshi Hirayama; Pasquale Lino Calvani; Argiris L Pissiotis
Journal:  Case Rep Dent       Date:  2013-12-08

8.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07

9.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08

10.  Surface characteristics and bioactivity of a novel natural HA/zircon nanocomposite coated on dental implants.

Authors:  Ebrahim Karamian; Amirsalar Khandan; Mahmood Reza Kalantar Motamedi; Hesam Mirmohammadi
Journal:  Biomed Res Int       Date:  2014-04-16       Impact factor: 3.411

View more