Literature DB >> 10634487

Microfabricated isoelectric focusing device for direct electrospray ionization-mass spectrometry.

J Wen1, Y Lin, F Xiang, D W Matson, H R Udseth, R D Smith.   

Abstract

A novel microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using laser micromachining. The IEF microchip incorporated a separation channel (50 micro x 30 micro x 16 cm), three fluid connectors, and two buffer reservoirs. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, which were isolated from the separation channel by porous membranes. Direct ESI-mass spectrometry (MS) using electrosprays produced directly from a sharp emitter "tip" on the microchip was evaluated. The results indicated that this design can produce a stable electrospray and that performance was further improved and made more flexible with the assistance of a sheath gas and sheath liquid. Error analysis of the spectral data showed that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 h. The production of stable electrosprays directly from microchip IEF device represents a step towards easily fabricated microanalytical devices. Microchannel IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. Direct microchannel IEF-ESI-MS was demonstrated using the microfabricated chip with an ion-trap mass spectrometer for characterization of protein mixtures.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10634487     DOI: 10.1002/(SICI)1522-2683(20000101)21:1<191::AID-ELPS191>3.0.CO;2-M

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  High yield sample preconcentration using a highly ion-conductive charge-selective polymer.

Authors:  Honggu Chun; Taek Dong Chung; J Michael Ramsey
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

2.  Field-free remobilization of proteins after isoelectric focusing in packed capillaries.

Authors:  Yimin Hua; Brooke M Koshel; Mary J Wirth
Journal:  Anal Chem       Date:  2010-10-08       Impact factor: 6.986

3.  Microfabricated PDMS multichannel emitter for electrospray ionization mass spectrometry.

Authors:  J S Kim; D R Knapp
Journal:  J Am Soc Mass Spectrom       Date:  2001-04       Impact factor: 3.262

Review 4.  Microchips, Microarrays, Biochips and Nanochips - Personal Laboratories for the 21st Century.

Authors:  Larry J Kricka
Journal:  EJIFCC       Date:  2000-12-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.