Literature DB >> 10626942

A new artifact-free device for frameless, magnetic resonance imaging-guided stereotactic procedures.

R L Bernays1, S S Kollias, N Khan, B Romanowski, Y Yonekawa.   

Abstract

OBJECTIVE: A new, artifact-free, nonobstructive device was required for planning, guiding, and performing stereotactic procedures in an open magnetic resonance imaging (MRI) system (Signa SP; General Electric, Milwaukee, WI). DESCRIPTION OF INSTRUMENTATION: We devised an MRI-compatible instrument set that was adapted to an optical triangulation system (FlashPoint System; Image Guided Technologies, Boulder, CO) and consisted of a Pathfinder for planning burr holes and trajectories and a Snapper-Stereoguide for guiding minimally invasive instruments such as biopsy cannulae, endoscopes, and laser fibers. The instruments were composed of biocompatible plastic (polyacetal). During evaluation, special attention was paid to safety, accuracy, operation times, and susceptibility artifacts of the system.
RESULTS: The first 20 stereotactic procedures performed in the open MRI scanner included 15 biopsies, 1 cyst and 3 abscess evacuations, and 1 endoscopic procedure for treatment of multiseptate hydrocephalus. There were no adverse outcomes, and all biopsies were diagnostic. The frameless stereotactic system in combination with the FlashPoint System proved to be accurate, with a mean error of 1.5 mm. The biopsy devices did not cause any susceptibility artifacts. Highly vascularized structures were clearly visible and were included in the trajectory planning. With experience, the procedure time was reduced to less than 1 hour.
CONCLUSION: This device was found to be quite helpful for planning and guiding stereotactic procedures in the open MRI scanner. Nearly real-time planning and monitoring of stereotactic procedures and the positional accuracy of the system make the open MRI system a definite improvement, compared with conventional stereotactic systems.

Entities:  

Mesh:

Year:  2000        PMID: 10626942

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  4 in total

1.  Use of a disposable real-time CT stereotactic navigator device for minimally invasive dog brain biopsy through a mini-burr hole.

Authors:  Thomas Flegel; Michael Podell; Philip A March; Donald W Chakeres
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

2.  Focused ultrasound-mediated suppression of chemically-induced acute epileptic EEG activity.

Authors:  Byoung-Kyong Min; Alexander Bystritsky; Kwang-Ik Jung; Krisztina Fischer; Yongzhi Zhang; Lee-So Maeng; Sang In Park; Yong-An Chung; Ferenc A Jolesz; Seung-Schik Yoo
Journal:  BMC Neurosci       Date:  2011-03-06       Impact factor: 3.288

3.  UniversitätsSpital Zürich: 80 years of neurosurgical patient care in Switzerland.

Authors:  Martin N Stienen; Carlo Serra; Lennart H Stieglitz; Niklaus Krayenbühl; Oliver Bozinov; Luca Regli
Journal:  Acta Neurochir (Wien)       Date:  2017-11-13       Impact factor: 2.216

4.  The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note.

Authors:  Martin N Stienen; Jorn Fierstra; Athina Pangalu; Luca Regli; Oliver Bozinov
Journal:  Oper Neurosurg (Hagerstown)       Date:  2019-06-01       Impact factor: 2.703

  4 in total