Literature DB >> 10606938

Nasal lavage mediator profile and cellular composition of nasal brushing material during latex challenge tests.

M Raulf-Heimsoth1, C Wirtz, F Papenfuss, X Baur.   

Abstract

BACKGROUND: Recent studies have shown that airborne latex allergens cause allergic rhinitis and bronchial asthma.
OBJECTIVE: The aim of this study was to investigate the association between the development of rhinitis reactions during workplace-related inhalative challenge tests and nasal allergic inflammation.
METHODS: Thirty-two health care workers (HCWs) with suspected respiratory hypersensitivity to latex allergens underwent an inhalative workplace-related challenge test with powdered latex gloves. Nasal lavage fluid (NALF) and nasal brushing (NAB) material were collected before and after exposure (30 min, 2, 6 and 24 h) to determine mediator and cellular composition. In addition, lung function parameters and nasal flow were recorded. Furthermore, six healthy controls underwent nasal brushing and nasal lavage without latex allergen challenge at the same time intervals.
RESULTS: Twenty-six HCWs showed acute rhinitis by contact to airborne latex allergen exposure and 10 of them had an additional asthma response. Only in responders, significantly increased eosinophil levels were found 6 h (P < 0.00001) and 24 h (P < 0.0005) post-challenge when compared with the prechallenge values. The ECP levels measured 2, 6 and 24 h post-challenge in the responder group were significantly elevated when compared with the prechallenge values as well as with the non-responders (6 h: P < 0.05, 24 h: P < 0.00001 afterwards). Only in some concentrated NALF samples of responders collected 30 min post-challenge (seven out of 15) tryptase concentration above the detection limit were found. The NO derivative concentrations in NALF were significantly increased 6 h post-challenge compared with the prechallenge values (P < 0.05) and were significantly higher in responders than in non-responders and in controls (P < 0.002). IL-5 levels increased post-challenge in the responder group with a pronounced effect 6 h after challenge (P < 0.001). Overall, a variety of parameters was significantly correlated (e.g. ECP with NO derivatives, r = 0.792 P < 0.002).
CONCLUSIONS: Our data demonstrate for the first time that nasal and bronchial hyperreactivity to airborne latex allergens are associated with an increase of eosinophils and mediators (e.g. ECP, NO derivatives, IL-5, tryptase) in nasal mucosa. The combined use of NAB (for cells) and NALF (for mediators) appears to be a useful model to monitor nasal inflammation during workplace-related challenge tests.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10606938     DOI: 10.1046/j.1365-2222.2000.00690.x

Source DB:  PubMed          Journal:  Clin Exp Allergy        ISSN: 0954-7894            Impact factor:   5.018


  7 in total

Review 1.  Cytokine expression in allergic inflammation: systematic review of in vivo challenge studies.

Authors:  Manuel A R Ferreira
Journal:  Mediators Inflamm       Date:  2003-10       Impact factor: 4.711

2.  Nasal blown secretion evaluation in specific occupational nasal challenges.

Authors:  Patrizia Pignatti; Gianni Pala; Marta Pisati; Luca Perfetti; Gabriella Banchieri; Gianna Moscato
Journal:  Int Arch Occup Environ Health       Date:  2009-08-23       Impact factor: 3.015

3.  Lower airway disease in asthmatics with and without rhinitis.

Authors:  Anne E Dixon; Danielle M Raymond; Benjamin T Suratt; Lorraine M Bourassa; Charles G Irvin
Journal:  Lung       Date:  2008-10-09       Impact factor: 2.584

4.  Diesel exposure suppresses natural killer cell function and resolution of eosinophil inflammation: a randomized controlled trial of exposure in allergic rhinitics.

Authors:  Erica A Pawlak; Terry L Noah; Haibo Zhou; Claire Chehrazi; Carole Robinette; David Diaz-Sanchez; Loretta Müller; Ilona Jaspers
Journal:  Part Fibre Toxicol       Date:  2016-05-06       Impact factor: 9.400

5.  Nasal Cytology: A Comparative Study of Two Different Techniques of Processing-Smeared versus Cytocentrifuged Slides.

Authors:  Maria Laura Bartoli; Lodovica Cristofani-Mencacci; Mariella Scarano; Andrea Nacci; Manuela Latorre; Elena Bacci; Pierluigi Paggiaro; Veronica Seccia
Journal:  Mediators Inflamm       Date:  2018-11-14       Impact factor: 4.711

Review 6.  EAACI position paper on occupational rhinitis.

Authors:  Gianna Moscato; Olivier Vandenplas; Roy Gerth Van Wijk; Jean-Luc Malo; Luca Perfetti; Santiago Quirce; Jolanta Walusiak; Roberto Castano; Gianni Pala; Denyse Gautrin; Hans De Groot; Ilenia Folletti; Mona Rita Yacoub; Andrea Siracusa
Journal:  Respir Res       Date:  2009-03-03

7.  Burnt sugarcane harvesting is associated with rhinitis symptoms and inflammatory markers.

Authors:  Iara Buriola Trevisan; Ubiratan de Paula Santos; Marceli Rocha Leite; Aline Duarte Ferreira; Bruna Spolador de Alencar Silva; Ana Paula Coelho Figueira Freire; Gabriel Faustino Santa Brigida; Ercy Mara Cipulo Ramos; Dionei Ramos
Journal:  Braz J Otorhinolaryngol       Date:  2018-04-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.