Literature DB >> 10604694

Hydrogel/silver ion-coated urinary catheter reduces nosocomial urinary tract infection rates in intensive care unit patients: a multicenter study.

R A Bologna1, L M Tu, M Polansky, H D Fraimow, D A Gordon, K E Whitmore.   

Abstract

OBJECTIVES: Indwelling urinary catheters are the leading source of nosocomial urinary tract infections (NUTIs). The Bardex I.C. catheter is a hydrogel latex Foley catheter with a monolayer of silver metal applied to the inner and outer surfaces of the catheter. We investigated the Bardex I.C. catheter for its ability to decrease the NUTI rate in critical care units.
METHODS: Five hospitals participated in a blind prospective study, exchanging the standard latex Foley catheter for the Bardex I.C. Foley catheter. The device use rate and NUTI rate were monitored. Data were collected and analyzed using Wilcoxon rank sum test and four-way analysis of variance. A cost analysis was also performed.
RESULTS: The baseline period, intervention period, and number of device days was similar for both periods. The unadjusted catheter-associated infection rate during the baseline and intervention periods was 7.1 and 4.5 infections per 1000 catheter days, respectively (P <0.01). The adjusted catheter-associated infection rate during the baseline and intervention periods was 8.1 and 4.9 infections per 1000 catheter days, respectively. This was not statistically significant (P = 0. 13).
CONCLUSIONS: A trend toward a reduction in NUTIs with the use of the hydrogel/silver-coated catheter was noted in all intensive care units at each institution as shown by the unadjusted and adjusted catheter-associated infection rates. One hospital demonstrated a statistically significant reduction in NUTIs. However, statistical significance was not met when the results were adjusted. The cost analysis at one institution demonstrated cost savings with the use of the silver-coated catheter. Future analysis may require a double-blind, prospective-controlled study of longer duration to reach statistical significance.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10604694     DOI: 10.1016/s0090-4295(99)00318-0

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  11 in total

1.  Biocompatibility analysis of an electrically-activated silver-based antibacterial surface system for medical device applications.

Authors:  Meghan E Samberg; Zhuo Tan; Nancy A Monteiro-Riviere; Paul E Orndorff; Rohan A Shirwaiker
Journal:  J Mater Sci Mater Med       Date:  2012-12-16       Impact factor: 3.896

2.  Prevention and treatment of urinary catheter-associated infections.

Authors:  Mayar Al Mohajer; Rabih O Darouiche
Journal:  Curr Infect Dis Rep       Date:  2013-04       Impact factor: 3.725

Review 3.  Technologic advances in endotracheal tubes for prevention of ventilator-associated pneumonia.

Authors:  Juan F Fernandez; Stephanie M Levine; Marcos I Restrepo
Journal:  Chest       Date:  2012-07       Impact factor: 9.410

Review 4.  A scoping review of important urinary catheter induced complications.

Authors:  K H Dellimore; A R Helyer; S E Franklin
Journal:  J Mater Sci Mater Med       Date:  2013-05-10       Impact factor: 3.896

5.  In vitro efficacy of a novel active-release antimicrobial coating to eradicate biofilms of Pseudomonas aeruginosa.

Authors:  Dustin L Williams; Julia M Lerdahl; Bryan S Haymond; Roy D Bloebaum
Journal:  Antimicrob Agents Chemother       Date:  2014-01-06       Impact factor: 5.191

Review 6.  Use of silver in the prevention and treatment of infections: silver review.

Authors:  Amani D Politano; Kristin T Campbell; Laura H Rosenberger; Robert G Sawyer
Journal:  Surg Infect (Larchmt)       Date:  2013-02-28       Impact factor: 2.150

7.  Proteolytically activated anti-bacterial hydrogel microspheres.

Authors:  Jason S Buhrman; Laura C Cook; Jamie E Rayahin; Michael J Federle; Richard A Gemeinhart
Journal:  J Control Release       Date:  2013-06-28       Impact factor: 9.776

8.  In vivo efficacy of a silicone‒cationic steroid antimicrobial coating to prevent implant-related infection.

Authors:  Dustin L Williams; Bryan S Haymond; James P Beck; Paul B Savage; Vinod Chaudhary; Richard T Epperson; Brooke Kawaguchi; Roy D Bloebaum
Journal:  Biomaterials       Date:  2012-08-30       Impact factor: 12.479

Review 9.  Catheter-Associated Urinary Infections and Consequences of Using Coated versus Non-Coated Urethral Catheters-Outcomes of a Systematic Review and Meta-Analysis of Randomized Trials.

Authors:  Vineet Gauhar; Daniele Castellani; Jeremy Yuen-Chun Teoh; Carlotta Nedbal; Giuseppe Chiacchio; Andrew T Gabrielson; Flavio Lobo Heldwein; Marcelo Langer Wroclawski; Jean de la Rosette; Rodrigo Donalisio da Silva; Andrea Benedetto Galosi; Bhaskar Kumar Somani
Journal:  J Clin Med       Date:  2022-07-30       Impact factor: 4.964

10.  Efficacy of Noble Metal–alloy Endotracheal Tubes in Ventilator-associated Pneumonia Prevention: a Randomized Clinical Trial

Authors:  Radu Ciprian Tincu; Cristian Cobilinschi; Iulia Florentina Tincu; Radu Alexandru Macovei
Journal:  Balkan Med J       Date:  2022-03-25       Impact factor: 3.570

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.